Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio MPC8002SP — Trang 45/63

Code: SC720-04

Description: Protection device break error 1 (2000/3000-sheet finisher with Mailbox). Protection device break error (fuse tripped)
Causes: • Short-circuit • Overload • Motor/solenoid defective
Remedy: 2000/3000-sheet finisher • Check the harness. • Replace the PCB. Mailbox • Check the harness. • Replace the PCB. • Replace the motor/solenoid.

Code: SC720-10 ... SC720-13

Description: SC720-10 B Entrance Transport Motor Error (2000/3000 SC720-11 B Horizontal Transport Motor Error (2000/3000 SC720-12 B Pre Stack Transport Motor Error (2000/3000 SC720-13 B Middle Transport Motor Error (2000/3000). Motor driver detected an error (DC motor control error). (The first time: jam display, the second time: SC)
Causes: • Motor defective • Connecter disconnected • Overload • Encoder defective
Remedy: • Check motor connection. • Replace the motor. • Replace the PCB.

Code: SC720-16

Description: Tray Exit Motor Error (2000/3000 Motor driver detected an error (DC motor control error). (The first time: jam display, the second time: SC)
Causes: • Motor defective • Connecter disconnected • Overload • Encoder defective
Remedy: • Check motor connection. • Replace the motor. • Replace the PCB.

Code: SC720-20

Description: Lower Junction Gate Motor Error (2000/3000) •Motor driver detected an error (short-circuit or overheat). (SC from the first time) • When moving to the home position, home position was not detected within specified number of pulses (p0 pulses). (The first time: jam display, the second time: SC) • When moving from the home position, home position was still detected after specified number of pulses (p1 pulses). (The first time: jam display, the second time: SC)
Causes: • Motor defective • Connecter disconnected • Overload • Home position sensor defective
Remedy: • Check the connections of the motor and home position sensor. • Replace the motor/home position sensor. • Replace the PCB.

Code: SC720-24

Description: Paper Exit Gate Motor Error (2000/3000) • Motor driver detected an error (short-circuit or overheat). (SC from the first time) • When moving to the home position, home position was not detected within specified number of pulses (p0 pulses). (The first time: jam display, the second time: SC) • When moving from the home position, home position was still detected after specified number of pulses (p1 pulses). (The first time: jam display, the second time: SC)
Causes: • Motor defective • Connecter disconnected • Overload • Home position sensor defective
Remedy: • Check the connections of the motor and home position sensor. • Replace the motor/home position sensor. • Replace the PCB.

Code: SC720-25

Description: Punch Motor Error (2000/3000) • When moving to the home position, home position was not detected within specified number of pulses (p0 pulse). (The first time: jam display, the second time: SC) • When moving from the home position, home position was still detected after specified number of pulses (p1 pulses). (The first time: jam display, the second time: SC)
Causes: • Motor defective • Connecter disconnected • Overload • Home position sensor defective
Remedy: • Check the connections of the motor and home position sensor. • Replace the motor/home position sensor. • Replace the PCB.

Code: SC720-27

Description: Punch Drive Motor Error (2000/3000) • When moving to the home position, home position was not detected within specified number of pulses (p0 pulse). (The first time: jam display, the second time: SC) • When moving from the home position, home position was still detected after specified number of pulses (p1 pulses). (The first time: jam display, the second time: SC)
Causes: • Motor defective • Connecter disconnected • Overload • Home position sensor defective
Remedy: • Check the connections of the motor and home position sensor. • Replace the motor/home position sensor. • Replace the PCB.

Code: SC720-28

Description: Paper Position Sensor Side Motor Error (2000/3000) • When moving to the home position, home position was not detected within specified number of pulses (p0 pulse). (The first time: jam display, the second time: SC) • When moving from the home position, home position was still detected after specified number of pulses (p1 pulses). (The first time: jam display, the second time: SC)
Causes: • Motor defective • Connecter disconnected • Overload • Home position sensor defective
Remedy: • Check the connections of the motor and home position sensor. • Replace the motor/home position sensor. • Replace the PCB.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie