Mã lỗi Ricoh Aficio Pro C550EX — Trang 20/35
Description: Controller fan error
The lock signal remained HIGH for 5 sec. while the fan that cools the printed circuit boards was operating.
Causes: • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
Description: Fusing unit suction fan error
The lock signal remained HIGH for 5 sec. while the fan that draws air out of the fusing unit was operating.
Causes: • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
Description: Duplex unit fan error
The lock signal remained HIGH for 5 sec. while the fan that draws air out of the duplex unit was operating.
Causes: • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
Description: Development Intake Fan Error
The lock signal remained HIGH for 5 sec. while the fan in the Y development unit was operating
Causes: • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
Description: Development Intake Fan Error: Y
The lock signal remained HIGH for 5 sec. while the fan in the development unit was operating.
Causes: • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
Description: Development Intake Fan Error: C
The lock signal remained HIGH for 5 sec. while the fan in the development unit was operating.
Causes: • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
Description: Development Intake Fan Error: M
The lock signal remained HIGH for 5 sec. while the fan in the development unit was operating.
Causes: • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged
Description: Development Intake Fan Error: K
The lock signal remained HIGH for 5 sec. while the fan in the development unit was operating.
Causes: • Fan harness disconnected or damaged • Fan blocked by an obstruction • Fan damaged