Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio Pro C720S — Trang 40/85

Code: 632

Description: Counter device error 1 After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms.
Causes: • Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged • Make sure that SP5113 is set to enable the optional counter device.
Remedy:

Code: 633

Description: Counter device error 2 After communication is established, the controller receives the break signal from the accounting device.
Causes: • Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged • Make sure that SP5113 is set to enable the optional counter device.
Remedy:

Code: 634

Description: Counter device error 3 A backup RAM error was returned by the counter device.
Causes: • Counter device control board defective • Backup battery of counter device defective
Remedy:

Code: 635

Description: Counter device error 4 A backup battery error was returned by the counter device.
Causes: • Counter device control board defective • Backup battery of counter device defective
Remedy:

Code: 641

Description: BCU control data transfer abnormal A sampling of the control data sent from the BCU reveals an abnormality.
Causes: • Controller board defective • External noise • BCU board defective
Remedy: 1. Replace the controller board. 2. Replace the BCU board.

Code: 650

Description: Communication error of the remote service modem (Embedded RCG-M)
Causes: -001 CTL B Authentication error The authentication for the Embedded RCG-M fails at a dial up connection. • Incorrect SP settings • Disconnected telephone line • Disconnected modem board Check and set the correct user name (SP5816-156) and password (SP5816-157). -004 CTL B Incorrect modem setting Dial up fails due to the incorrect modem setting. • Same as -001 Check and set the correct AT command (SP5816-160). -005 - Communication line error The supplied voltage is not sufficient due to a defective communication line or defective connection. • Same as -001 Consult with the user's local telephone company. -011 - Incorrect network setting Both the NIC and Embedded RCG-M are activated at the same time. • Same as -001 Disable the NIC with SP5985-1. -012 - Modem board error The modem board does not work properly even though the setting of the modem board is installed with a dial up connection. • Same as -001 1. Install the modem board. 2. Check and reset the modem board setting with SP5816. 3. Replace the modem board.
Remedy:

Code: 651

Description: Incorrect dial up connection
Causes: -001 CTL C Program parameter error -002 CTL C Program execution error An unexpected error occurs when the modem (Embedded RCG-M) tries to call the center with a dial up connection.
Remedy: • Caused by a software bug

Code: 660

Description: Timer error The machine fails to read the internal timer.
Causes: • Defective engine firmware
Remedy: Update the engine firmware to the latest version.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie