Code: 129

Description: Scanner Motor Error 5 (D016/D097 only) The scanner motor speed is abnormal. The machine will not stop scanning even after the machine detects that motor speed is abnormal.
Causes: • Scanner motor defective • Scanner drive mechanism defective • PSU-Eb board defective • MCU board defective (scanner motor control unit)
Remedy:

Code: 141

Description: Black level detection error (D016/D097 only) When the scanner was turned on, AGC (automatic gain control) failed to achieve the target value of 10 ±3.
Causes: • SBU to IPU harnesses defective • BCU to IPU harnesses defective • SBU defective • IPU defective • BCU defective
Remedy:

Code: 142

Description: White level detection error (D016/D097 only) When the scanner was turned on, the second sampling by AGC (automatic gain control) failed to achieve a value within the range – 7 to 0 of the target value 128.
Causes: • Standard white plate defective, dirty • Moisture inside the scanner unit • SBU to IPU harnesses defective • BCU to IPU harnesses defective • SBU defective • IPU defective • BCU defective
Remedy:

Code: 143

Description: SBU Error 1 (D016/D097 only) When the scanner was turned on, the SBU (Sensor Board Unit) level adjustment, black level check, and final SBU white level check failed.
Causes: • SBU defective • IPU defective • BCU defective • Harness between the SBU and IPU defective • Harness between the BCU-IPU defective • Standard white plate not installed correctly, or is dirty • Scanner mirrors and/or lenses are dirty or installed incorrectly
Remedy:

Code: 144

Description: SBU Error 2 (D016/D097 only) At power on: The SYDI terminal signal did not go HIGH within 1 s The specified SBU (Sensor Board Unit) ID (GASBUP and LM98513) could not be read after 3 tries
Causes: • SBU defective • BCU defective • Harness between SBU and IPU defective
Remedy:

Code: 161

Description: IPU Error At power on, or when the machine returns from an energy save mode, the self-diagnostic program returned an IPU error.
Causes: • IPU defective • Connection between SBU and IPU is loose, broken, or defective
Remedy:

Code: 180

Description: Scanner Unit Fan Error: Scanner Intake Fan (D016/D097 only) The MCU issued a lock signal fro the scanner intake fan (rear, right).
Causes: • Fan, MCU, SIB harnesses loose or defective • Scanner intake fan motor defective • MCU defective • SIB defective
Remedy:

Code: 181

Description: Scanner Unit Fan Error: Lamp Regulator Fan (Right) (D016/D097 only) The MCU issued a lock signal for the lamp regulator fan (front, right).
Causes: • Fan, MCU harness loose, defective • Lamp regulator (right) fan motor defective • MCU defective • SIB defective
Remedy:
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie