Description: Sub Grip HP Sensor (S37) Error PB (D391) The sub grip HP sensor did not go ON within the prescribed time after the sub grip lift motor turned on to raise the sub grip unit. -or- The sub grip HP sensor did not go OFF within the prescribe time after the sub grip lift motor turned on to lower the sub grip unit.
Causes: • Sub Grip Lift Motor (M17) defective • Sub Grip HP Sensor (S37) defective • Sensor or motor connector loose, broken, defective
Remedy:
Code: 796-32
Description: Sub Grip Size HP Sensor (S38) Error PB (D391)
Causes: The sub grip size HP sensor did not go ON within the prescribed time after the sub grip size motor turned on for horizontal adjustment to the paper size. -or- The sub grip size HP sensor was already OFF when the sub grip size horizontal adjustment started (from the open to closed position). • Sub Grip Size Motor (S19) defective • Sub Grip Size HP Sensor (S38) defective • Motor or sensor connector loose, broken, defective The sub grip size HP sensor did not go OFF within the prescribed time after the sub grip size motor turned on to close sub grippers for horizontal adjustment of the paper size. -or- The sub grip size HP sensor was already ON when the sub grip size horizontal adjustment started (from the close to open position). • Sub Grip Size Motor (S19) defective • Sub Grip Size HP Sensor (S38) defective • Motor or sensor connector loose, broken, defective
Remedy:
Code: 796-33
Description: Sub Grip Open Sensor (S40) Error PB (D391) The sub grip open sensor did not go ON within the prescribed time after the sub grip lift motor turned on to open the sub grip unit. -or- The sub grip open sensor did not go OFF within the prescribed time after the sub grip lift motor turned on to close the sub grip unit.
Causes: • Sub Open Motor (S20) defective • Sub Grip Open Sensor (S40) defective • Motor or sensor connector loose, broken, defective
Remedy:
Code: 796-34
Description: Sub Grip Close Sensor (S41) Error PB (D391) The sub grip close sensor did not go ON within the prescribed time after the sub grip lift motor turned on to close the sub grip unit. -or- The sub grip close sensor did not go OFF within the prescribed time after the sub grip open motor turned on to open the sub grip unit.
Causes: • Sub Grip Open Motor (S20) defective • Sub Grip Open Close (S41) defective • Motor or sensor connector loose, broken, defective
Remedy:
Code: 796-35
Description: Sub Grip Dual Sensor Error PB (D391) The Sub Grip Open Sensor (S40) and Sub Grip Close Sensor (S41) went ON at the same time.
Causes: • Sub Grip Open Sensor (S40) defective • Sub Grip Close Sensor (S41) defective • A sensor connector loose, broken, defective
Remedy:
Code: 796-36
Description: Signature HP Sensor (S34) Error PB (D391) The signature HP sensor did not go ON within the prescribed time after the signature move motor turned on to move the sub grip to the home position. -or- The signature HP sensor did not go OFF within the prescribed time after the signature move motor turned on to move the sub grip to the signature transfer position (from sub grip to main grip).
Causes: • Signature Move Motor (M18) defective • Signature HP Sensor (S34) defective • Connector loose, broken, defective
Remedy:
Code: 796-37
Description: Signature Main Grip Position Sensor (S35) Error PB (D391)
Causes: The signature main grip position sensor did not go ON within the prescribed time after the signature move motor turned for delivery of the signature from the sub grip to the main grip. -or- Due to incorrect timing during delivery of the signature from sub grip to main grip, the signature was gripped at the main grip HP sensor position. • Signature Move Motor (M18) defective • Signature Main Grip Position Sensor (M35) defective • Motor or sensor connector loose, broken, defective The signature HP sensor did not go OFF within the prescribed time after the signature move motor turned on to move the sub grip to the home position. • Signature Move Motor (M18) defective • Signature Main Grip Position Sensor (M35) defective • Motor or sensor connector loose, broken, defective
Remedy:
Code: 796-38
Description: Main Grip Rotate Enable Sensor (S36) Error PB (D391) The main grip rotate enable sensor did not go ON within the prescribe time after the signature move motor turned on to move the sub grip to the home position. -or- The main grip rotate enable sensor did not go OFF within the prescribed time after the signature move motor turned on to move the sub grip to the signature transfer position (from sub grip to main grip).
Causes: • Signature Move Motor (M18) defective • Main Grip Rotate Enable Sensor (S36) defective • Motor or sensor connector loose, broken, defective