Các lỗi thường gặp

Code :
  • Code: SC542
  • Description: Fusing Reload Temperature Error (Fatal Error)
  • Causes: After starting up or during operation he machine detected after 5 readings at 1.5 sec. intervals that the hot roller was 5°C below the reload (operating) temperature.
  • Remedy: • Fusing thermistor deformed or out of position • Fusing lamp harness loose, broken, defective • Fusing unit defective • After servicing the machine to solve the problem, the service technician must execute a "Fuser SC Reset". Otherwise, the machine will continue to issue this SC code and cannot be operated.
  • Code: SC543
  • Description: High Temperature Error - Software (Fatal Error)
  • Causes: The temperature inside the fusing unit exceeded 225°C (437°F) for more than 1 sec.
  • Remedy: • After this error has occurred three times, the machine will shut down and must be released with the Smart Organizing Monitor and serviced by a service technician. • Main board defective • PSU defective (TRIAC short) • After servicing the machine to solve the problem, the service technician must execute a "Fuser SC Reset". Otherwise, the machine will continue to issue this SC code and cannot be operated.
  • Code: SC544
  • Description: High Temperature Error- Hardware (Fatal Error)
  • Causes: The machine detected the CPU port LOW twice at 100 ms intervals and issued this SC. This check is always done to check for overheating, even if SC543 does not detect the problem.
  • Remedy: • Fusing unit defective • Main board defective • PSU defective (TRIAC short) • After servicing the machine to solve the problem, the service technician must execute a "Fuser SC Reset". Otherwise, the machine will continue to issue this SC code and cannot be operated.
  • Code: SC545
  • Description: Fusing Lamp Remains ON Error (Fatal Error)
  • Causes: The heating element of the fusing lamp remained at full power longer than 9 sec. after the reload temperature was detected.
  • Remedy: • Fusing thermistor harness connector loose, broken, defective • Fusing thermistor warped or positioned incorrectly • Fusing lamp harness connector loose, broken, defective • After servicing the machine to solve the problem, the service technician must execute a "Fuser SC Reset". Otherwise, the machine will continue to issue this SC code and cannot be operated.
  • Code: SC547
  • Description: Zerocross Error
  • Causes: Power supply frequency is unstable. HVP or PSU failure.
  • Remedy: • To reset the SC code, turn the power On and Off. • Use more stable power supply. • Replace the HVP or PSU.
  • Code: SC557
  • Description: Zerocross Frequency Over
  • Causes: Power supply frequency is unstable.
  • Remedy: No error message will be issued on this SC. A log of this SC will be logged in the SOM service mode SC
  • Code: SC559
  • Description: Fusing Unit Third Jam Error (Fatal Error)
  • Causes: The exit sensor failed to detect the leading edge of the paper within the prescribed time and triggered a jam alert.
  • Remedy: • After this error has occurred three times, the machine will shut down automatically and cannot be re-started until the machine has been serviced by a service technician. • Check the paper transport path for any physical obstructions (paper scraps, etc.) • Make sure the fusing unit has been installed correctly • After servicing the machine to solve the problem, the service technician must execute a "Fuser SC Reset". Otherwise, the machine will continue to issue this SC code and cannot be operated.
  • Code: SC587
  • Description: Motor Thermistor Error
  • Causes: After starting up, inside of the machine temperature would be checked every 100ms, then the machine is detected -30°C for 4 sec. or 105°C for a sec.
  • Remedy: • Check the connection or replace the thermistor • Replace the I/F harness • Replace main board