Code: 621

Description: Communication error – FCI I2C
The engine board detected an unknown device on the I2C I/F bus (internal bus on the engine control board). The engine board detected an I2C I/F bus error. The number of devices connected to the I2C bus exceeded 12.
Causes: • Engine board defectiveI I2C

Code: 634

Description: Key/card counter device error 3
The backup battery of the counter device RAM is low.
Causes: • Replace the RAM backup battery.

Code: 635

Description: Key/card counter device error 4
After installation of the device a message alerts user to a battery voltage abnormal error.
Causes: • Device control board defective • Device control board backup battery defective

Code: 650

Description: Communication error – GAVD I2C
The engine board detected an unknown device on the I2C I/F bus (internal bus on the engine control board). The engine board detected an I2C I/F bus error. The number of devices connected to the I2C bus exceeded 12.
Causes: • Engine board defective

Code: 651

Description: Communication error – FCI I2C
The engine board detected an unknown device on the I2C I/F bus (internal bus on the engine control board). The engine board detected an I2C I/F bus error. The number of devices connected to the I2C bus exceeded 12.
Causes: • Engine board defectiveI I2C

Code: 669

Description: NVRAM Error
The NVRAM was not connected at power on, or read/write operations on the NVRAM failed.
Causes: • NVRAM connected improperly • NVRAM missing

Code: 670

Description: Engine startup error
The BCU failed to respond with the prescribed time when the machine was turned on.
Causes: • Connections between BCU and controller board are loose, disconnected, or damaged • Replace the BCU • Replace the controller board

Code: 672

Description: Controller startup error
After power on, the line between the controller and the operation panel did not open for normal operation. After normal startup, communication with the controller stopped.
Causes: • Controller stalled • Controller installed incorrectly • Controller board defective • Operation panel harness disconnected or defective