Description: Polygon motor error
The polygon motor did not enter the lock state within 20 sec. after it switched on. -or- Once the polygon motor was detected in the lock state after started to rotate, within 0.6 sec. it entered the unlock state.. -or- After the polygon motor switched off, it did not enter unlock state within 20 sec.
Description: 1st beam laser synchronization error
With all doors closed the polygon motor is locked and not rotating, or the laser synchronization detector could not detect 1st beam laser detection signal within 5 ms..
Causes: • Laser synchronization detector board out of position • Laser synchronization detector board or cable defective • Laser synchronization mirror out of position • LD unit defective • Engine board defective
Description: 2nd beam laser synchronization error
With all doors closed the polygon motor is locked and not rotating, or the laser synchronization detector could not detect 2nd beam laser detection signal within 500 ms.
Causes: • Laser synchronization detector board out of position • LD unit defective • Engine board defective
Description: Fusing thermistor error
The fusing temperature did not rise higher than 20C within 11 sec. after the main motor switched off. -or- The fusing temperature was detected lower than 0oC for over 1 sec. after the power relay switched on.