Code: SC532-00

Description: PSU Cooling fan error
Causes: The fan motor lock (rotating state) signal is sampled at 100 ms intervals and the machine fails to receive the lock signal 50 times in succession. • Failed fan motor • Disconnected connector
Remedy: • Replace the fan motor. • Check the connector. • Replace the harness. • Replace the IOB.

Code: SC541-00

Description: Broken fusing (Center) thermistor wire
Causes: The condition whereby the temperature is -20 deg C or less for 5 seconds has been detected 10 times or more. • Broken thermistor wire • Bad connector contact
Remedy: • Clear the SP: fusing SC. • Check the connector connection. • Replace the fusing (Center) thermistor.

Code: SC542-01

Description: Fusing lamp (Center) thermistor not reloaded 1
Causes: The heater thermistor has increased by less than 2.0 degrees in 1.5 seconds 5 times in a row. • Deformed or floating thermistor • Input voltage out of range
Remedy: • Clear the SP: fusing SC. • Replace the thermistor.

Code: SC542-02

Description: Fusing lamp (Center) thermistor not reloaded 2
Causes: The heater (Center) thermistor does not reach the reload temperature 50 seconds after the start of motor rotation. • Fusing lamp disconnected • The overtemperature prevention mechanism started working
Remedy: • Clear the SP: fusing SC. • Replace the thermistor.

Code: SC543-00

Description: Fusing (Center) thermopile high-temperature detected (software)
Causes: The temperature is detected to stay at 245 deg C or higher for one second. • Shorted triac • Failed Engine Board
Remedy: • Clear the SP: fusing SC. • Replace the PSU. • Replace the Engine Board.

Code: SC544-00

Description: Fusing (Center) thermopile high-temperature detected (hardware)
Causes: The hardware high-temperature error sensor flag is detected. • Damaged triac (shorted) • Failed engine control board • Failed fusing thermopile • Failed fusing thermistor • Abnormal fusing control software behavior • The PWM signal is continuously supplied from the IH inverter (due to a software or temperature sensor error).
Remedy: • Clear the SP: fusing SC. • Replace the PSU. • Replace the Engine Board. • Replace the fusing thermopile. • Replace the Fusing Unit.

Code: SC545-00

Description: Fusing (Center) lamp stays ON
Causes: The thermistor (center) has not detected the target temperature, even after the fusing lamp stays ON for more than 30 seconds after reloading. • Deformed or floating thermistor • Broken fusing lamp wire • The overtemperature prevention mechanism started working
Remedy: • Clear the SP: fusing SC. • Replace the fusing thermistor. • Replace the fusing (Center) lamp.

Code: SC547-01

Description: Zero-crossing error (adhered relay contact)
Causes: When the fusing relay is in an OFF state, a "zero-crossing interrupt request" occurs in 50 ms. Damaged fusing relay (adhered contact)
Remedy: • Turn the main power OFF and then ON. • Replace the harness. • Replace the PC board. • Replace the PSU.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie