Mã lỗi Ricoh Aficio SP5210SF
Code:
Tất cả lỗi (105)
101
120
121
141
142
143
144
161-001
161-002
165
195
202
203
204
220
221
230
231
240
312
320
440
500
530
531
532
533
534
535
541
542
543
544
545
547
557
559
610
620
621
622
623
624
641
652
653
669
671
680-001
680-002
680-003
680-004
681
683
687
688
690
721
740
790
793
794
795
796
797
816
817
819
820
833
842
851
853
854
855
856
857
858
859
860
861
863
864
865
866
867
868
870
872
873
874
875
876
877
878
881
900
920
921
990
991
992
995
997
998
Description: Exposure lamp error 1 The standard white level setting dropped below the specified range during scanning.
Causes: • White plate dirty • Spurious electrical noise on power supply line • Exposure lamp connection loose, broken, defective • Exposure lamp defective • Lamp stabilizer connection, loose, broken, defective • Lamp stabilizer defective • High voltage power supply harness loose, broken, defective • SBU defective • BCU defective • SIO defective
Remedy:
Description: Scanner home position error 1 The scanner HP sensor did not turn off during scanner initialization or copying.
Causes: • Scanner motor harness loose, broken, defective at scanner motor or at BCU • Scanner HP sensor harness, loose, broken, defective at HP sensor or at BICU • Scanner motor or motor driver board defective • Scanner motor drive board defective • Scanner HP sensor defective
Remedy:
Description: Scanner home position error 2 The scanner HP sensor did not turn on during scanner initialization or copying.
Causes: • Scanner motor harness loose, broken, defective at scanner motor or at BCU • Scanner HP sensor harness, loose, broken, defective at HP sensor or at BICU • Scanner motor or motor driver board defective • Scanner motor drive board defective • Scanner HP sensor defective
Remedy:
Description: Black level correction error Black level correction could not be set properly during automatic adjustment.
Causes: • Harnesses at the SBU or BICU loose, broken, defective. • SBU defective
Remedy:
Description: White level correction error White level correction could not be set properly during automatic adjustment.
Causes: • Harnesses at SBU or BICU loose, broken, defective • Anti-condensation heater (option) in scanner unit not operating • Exposure lamp harness, loose, broken, defective • Exposure lamp defective • Scanner drive error • SBU defective
Remedy:
Description: SBU auto adjust error The machine could not acquire the white or black peak level setting at power on.
Causes: • Harnesses at SBU or BICU loose, broken, defective • Anti-condensation heater (option) in scanner unit not operating • Exposure lamp harness, loose, broken, defective • Exposure lamp defective • Scanner drive error • SBU defective
Remedy:
Description: SBU connection error Connection to the SBU could not be confirmed, possibly due to a defect in the BICU detection port.
Causes: • Harness connection at BICU or SBU loose, broken, defective • BICU defective • SBU defective
Remedy:
Description: IPU Error 1 The self-diagnostic test detected an error at the BICU at power on, or after the machine returned from energy save mode.
Causes: • Harness between SBU and BICU loose or broken • BICU defective • SBU defective
Remedy: