Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh Aficio SPC220S

Code: 195

Description: Serial Number Mismatch
• Serial number stored in the memory does not have the correct code.
Causes: • NVRAM defective • EGB replaced without original NVRAM
Remedy: 1. Check the serial number. 2. If the stored serial number is incorrect, contact your supervisor.

Code: 202

Description: Polygon motor error 1: ON timeout
The polygon mirror motor does not reach the targeted operating speed within the specified time after turning on or changing speed
Causes: • Defective or disconnected harness to polygon motor driver board • Defective polygon motor driver board • Defective polygon motor.
Remedy: 1. Replace the interface harness of the laser optics unit. 2. Replace the laser optics unit. 3. Replace the EGB (Engine Board).

Code: 203

Description: Polygon motor error 2: OFF timeout
The polygon mirror motor does leave the READY status within 3 seconds after the polygon motor switches off.
Causes: • Disconnected or defective harness to polygon motor driver board • Defective polygon motor driver board • Defective polygon motor.
Remedy: 1. Replace the interface harness of the laser optics unit. 2. Replace the laser optics unit. 3. Replace the EGB (Engine Board).

Code: 204

Description: Polygon motor error 3: XSCRDY signal error
The SCRDY_N signal goes HIGH (inactive) while the laser diode is firing.
Causes: • Disconnected or defective harness to polygon motor driver board • Defective polygon motor • Defective polygon motor driver board.
Remedy: 1. Replace the interface harness of the laser optics unit. 2. Replace the laser optics unit. 3. Replace the EGB (Engine Board).

Code: 220

Description: Laser Synchronizing Detection Error: [K]/[Y]
The laser synchronizing detection signal for LDB [K]/[Y] is not output after the LDB unit has turned on while the polygon motor is rotating normally.
Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LDB • Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser optics unit. 3. Replace the EGB.

Code: 224

Description: Laser Synchronizing Detection Error: [M]/[C]
The laser synchronizing detection signal for LDB [M]/[C] is not output after the LDB unit has turned on while the polygon motor is rotating normally.
Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LDB • Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser optics unit. 3. Replace the EGB.

Code: 240

Description: LD error
The IPU (EGB) detects a problem at the LD unit.
Causes: • Worn-out LD • Disconnected or broken harness of the LD.
Remedy: 1. Replace the laser optics unit.

Code: 300

Description: High voltage power output error
The measured voltage is not correct when the EGB measures each charge output (charge, development, image transfer belt unit, and transfer unit).
Causes: • Disconnected or defective high voltage harness • Defective high voltage power supply • Defective EGB
Remedy: 1. Check or replace the harnesses. 2. Replace the high voltage power supply board 3. Replace the EGB.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin