Description: Polygon motor error 1: ON timeout The polygon mirror motor does not reach the targeted operating speed within 5 sec. after turning on or changing speed.
Description: Polygon motor error 2: OFF timeout The polygon mirror motor does not leave the READY status within 3 sec. after the polygon motor switched off.
Description: Laser Synchronizing Detection Error: [K]/[Y] The laser synchronizing detection signal for LDB [K]/[Y] is not output after the LDB unit has turned on while the polygon motor is rotating normally.
Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LDB • Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser optics unit. 3. Replace the EGB.
Description: Laser Synchronizing Detection Error: [M]/[C] The laser synchronizing detection signal for LDB [M]/[C] is not output after the LDB unit has turned on while the polygon motor is rotating normally.
Causes: • Disconnected cable from the laser synchronizing detection unit or defective connection • Defective laser synchronizing detector • Defective LDB • Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser optics unit. 3. Replace the EGB.
Description: High voltage power output error The measured voltage is not correct when the EGB measures each charge output (charge, development, image transfer belt unit, and transfer unit).
Causes: • Disconnected or defective high voltage harness • Defective high voltage power supply • Defective EGB
Remedy: 1. Check or replace the harnesses. 2. Replace the high voltage power supply board 3. Replace the EGB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.