Mã lỗi Ricoh Aficio SPC312DN — Trang 4/4
Description: EEPROM Error
An unexpected value exists in the initialization flag of the EEPROM.
Causes: EEPROM not initialized. Defective EEPROM.
Remedy: 1. Initialize the EEPROM. 2. Replace the EEPROM. 3. Replace the EGB.
Description: GAVD Communication Error
The ID of the GAVD is not identified during initialization.
Causes: Defective EGB
Remedy: 1. Replace the EGB.
Description: Service Cycle Power
Incorrect combination of EGB and controller board. An unexpected error occurs in the EEPROM on the controller board
Causes: Controller board defective
Remedy: 1. Install the correct EGB and controller boards for this machine. 2. Replace the controller board
Description: USB/ Network Device Error
An interface error in the USB connection or NIB connection occurs.
Causes: Controller board detective
Remedy: 1. Replace the controller board.
Description: EEPROM Error
An EEPROM check error at power-on occurs.
Causes: Controller board detective
Remedy: 1. Replace the controller board.
Description: On-Board Memory Check Error
An on-board memory check error at power-on occurs.
Causes: Controller board detective
Remedy: 1. Replace the controller board.
Description: ROM Checksum Error
Causes: A ROM checksum error at power-on occurs.
Remedy: 1. Replace the controller board.