Mã lỗi Ricoh Aficio SPC411DN

Code: 195

Description: Incorrect serial number
When checking the registered product number, it does not match the printer’s product number.
Causes: Registered product number does not match the printer’s product number.
Remedy: 1. Ask your service key man.

Code: 202

Description: Polygon motor error: Time out with the polygon motor activated
After the polygon motor turns on or changes the speed, SCRDY_N is not active within 10 seconds.
Causes: Disconnected cable from the polygon motor drive board or defective connection. Defective polygon motor or drive board
Remedy: 1. Check the connectors. 2. Replace the polygon motor. 3. Replace the polygon motor drive board.

Code: 203

Description: Polygon motor error: Time out with the polygon motor inactivated
After the polygon motor turns off or changes the speed, SCRDY_N is not inactive within 10 seconds.
Causes: Disconnected cable from the polygon motor drive board or defective connection. Defective polygon motor or drive board
Remedy: 1. Check the connectors. 2. Replace the polygon motor. 3. Replace the polygon motor drive board.

Code: 204

Description: Polygon motor error: XSCRDY signal error
PMRDY_N signal consecutively detects that the polygon motor is an inactive state while LDB unit scans.
Causes: Disconnected cable from the polygon motor drive board or defective connection. Defective polygon motor or drive board
Remedy: 1. Check the connectors. 2. Replace the polygon motor. 3. Replace the polygon motor drive board.

Code: 205

Description: Polygon motor error: XSCRDY signal not stable
PMRDY_N signal consecutively detects that the polygon motor is an inactive state while the polygon motor turns on or changes the speed.
Causes: Disconnected cable from the polygon motor drive board or defective connection. Defective polygon motor or drive board.
Remedy: 1. Check the connectors. 2. Replace the polygon motor. 3. Replace the polygon motor drive board.

Code: 210

Description: Trailing edge laser detection error: [K]
The laser synchronizing detection signal for LDB [K] of the trailing edge is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
Causes: Disconnected cable from the laser synchronizing detection unit or defective connection. Defective laser synchronizing detector Defective LDB Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.

Code: 211

Description: Trailing edge laser detection error: [Y]
The laser synchronizing detection signal for LDB [Y] of the trailing edge is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
Causes: Disconnected cable from the laser synchronizing detection unit or defective connection. Defective laser synchronizing detector Defective LDB Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.

Code: 212

Description: Trailing edge laser detection error: [M]
The laser synchronizing detection signal for LDB [M] of the trailing edge is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
Causes: Disconnected cable from the laser synchronizing detection unit or defective connection. Defective laser synchronizing detector Defective LDB Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.