Description: Charge P.P. output error: M The feedback voltage of the charge AC for each color is 0.3 V or less for 200 ms after the charge AC has been turned on.
Causes: Disconnected or broken harnesses of the HVPS. Disconnected or broken PCU. Defective HVPS (C/B). Loose connection. Broken harness.
Remedy: • Reinstall or replace the harnesses of the HVPS. • Reinstall or replace the PCU. • Replace the HVPS (C/B). • Reconnect the connector.
Description: Charge P.P. output error: Y The feedback voltage of the charge AC for each color is 0.3 V or less for 200 ms after the charge AC has been turned on.
Causes: Disconnected or broken harnesses of the HVPS. Disconnected or broken PCU. Defective HVPS (C/B). Loose connection. Broken harness.
Remedy: • Reinstall or replace the harnesses of the HVPS. • Reinstall or replace the PCU. • Replace the HVPS (C/B). • Reconnect the connector.
Description: TD sensor adjustment error: K During TD sensor initialization, the output value of the black, cyan, magenta, or yellow TD sensor is not within the range of the specified value with SP3-238-001 to -004 (default: 2.5V)+-0.2V
Causes: A TD sensor-related part is faulty. A TD sensor-related part's connection is loose. The developer's toner thickness differs from that of the initial developer.
Remedy: • Turn the main power switch off and then back on. • Replace the PCU.
Description: TD sensor adjustment error: C During TD sensor initialization, the output value of the black, cyan, magenta, or yellow TD sensor is not within the range of the specified value with SP3-238-001 to -004 (default: 2.5V)+-0.2V
Causes: A TD sensor-related part is faulty. A TD sensor-related part's connection is loose. The developer's toner thickness differs from that of the initial developer.
Remedy: • Turn the main power switch off and then back on. • Replace the PCU.
Description: TD sensor adjustment error: M During TD sensor initialization, the output value of the black, cyan, magenta, or yellow TD sensor is not within the range of the specified value with SP3-238-001 to -004 (default: 2.5V)+-0.2V
Causes: A TD sensor-related part is faulty. A TD sensor-related part's connection is loose. The developer's toner thickness differs from that of the initial developer.
Remedy: • Turn the main power switch off and then back on. • Replace the PCU.
Description: TD sensor adjustment error: Y During TD sensor initialization, the output value of the black, cyan, magenta, or yellow TD sensor is not within the range of the specified value with SP3-238-001 to -004 (default: 2.5V)+-0.2V
Causes: A TD sensor-related part is faulty. A TD sensor-related part's connection is loose. The developer's toner thickness differs from that of the initial developer.
Remedy: • Turn the main power switch off and then back on. • Replace the PCU.
Description: TD sensor (Vt high) error 1: K The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3-020-002 for twenty counts. The [Vt - Vtref] value of the black, cyan, magenta, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3-020-001.
Causes: A TD sensor-related part is faulty. A TD sensor-related part's connection is loose. Toner density error.
Remedy: • Turn the main power switch off and then back on. • Replace the AIT (development unit).
Description: TD sensor (Vt high) error 1: C The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3-020-002 for twenty counts. The [Vt - Vtref] value of the black, cyan, magenta, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3-020-001.
Causes: A TD sensor-related part is faulty. A TD sensor-related part's connection is loose. Toner density error.
Remedy: • Turn the main power switch off and then back on. • Replace the AIT (development unit).
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.