Description: Exposure Lamp Error
At trigger on, the lamp was not detected on.
Causes: • Exposure lamp defective
• Lamp regulator defective
• Lamp regulator harness damaged, disconnected
• Dirty standard white plate
• Scanner mirror dirty or out of position
• Lens dirty, out of position
• SBU board defective
Description: SBU auto adjust error
Automatic adjustment of the SBU fails when the machine is switched on.
Causes: • Exposure lamp defective
• Exposure lamp regulator defective
• Harness between exposure lamp and lamp regulator is disconnected
• White plate installed incorrectly or is dirty
• Scanning mirrors of the exposure unit are dirty or out of position
• SBU board defective
• VIB board defective.
• Harness between SBU, VIB disconnected
• Harness between VIB, BCU disconnected
Description: SBU transmission error
After the SBU switches on, the BCU detects one of the following conditions on the SBU:
• 1 s after power on, the SYDI signal does not go high, even after 1 retry.
• 1 s after power on, the SYDI signal goes high, but the SBU ID could not be read after 3 attempts.
Causes: • SBU defective
• VIB defective
• Harness (40-pin shielded) between the SBU, VIB is disconnected
• Harness (shielded cable) between the VIB, BCU is disconnected