Các lỗi thường gặp

Code :
  • Code: 161
  • Description: IPU error
    The error result of self-diagnostic by the Taurus (ASIC on the IPU) is detected.
  • Causes: • Defective IPU • Defective connection between IPU and SBU
  • Remedy: 1. Check the connection between BICU and SBU. 2. Replace the BICU.
  • Code: 165
  • Description: Copy Data Security Unit error
    • The copy data security board is not detected when the copy data security function is set "ON" with the initial setting. • A device check error occurs when the copy data security function is set "ON" with the initial setting.
  • Causes: • Incorrect installation of the copy data security board • Defective copy data security board
  • Remedy: 1. Reinstall the copy data security board. 2. Replace the copy data security board.
  • Code: 195
  • Description: Serial Number Mismatch
    • Serial number stored in the memory does not have the correct code.
  • Causes: • NVRAM defective • BCU replaced without original NVRAM
  • Remedy: 1. Check the serial number with SP5-811-002. 2. If the stored serial number is incorrect, contact your supervisor.
  • Code: 202
  • Description: Polygon motor error 1: ON timeout
    The polygon mirror motor does not reach the targeted operating speed within the specified time after turning on or changing speed
  • Causes: • Defective or disconnected harness to polygon motor driver board • Defective polygon motor driver board • Defective polygon motor.
  • Remedy: 1. Replace the polygon motor. 2. Replace the laser optics housing unit. 3. Replace the harness. 4. Replace the BICU.
  • Code: 203
  • Description: Polygon motor error 2: OFF timeout
    The polygon mirror motor does leave the READY status within 3 seconds after the polygon motor switches off.
  • Causes: • Disconnected or defective harness to polygon motor driver board • Defective polygon motor driver board • Defective polygon motor
  • Remedy: 1. Check or replace the harness. 2. Replace the polygon motor.
  • Code: 204
  • Description: Polygon motor error 3: XSCRDY signal error
    The SCRDY_N signal goes HIGH (inactive) while the laser diode is firing.
  • Causes: • Disconnected or defective harness to polygon motor driver board • Defective polygon motor • Defective polygon motor driver board
  • Remedy: 1. Check or replace the harness. 2. Replace the polygon motor.
  • Code: 210
  • Description: Laser synchronizing detection error: end position [K]
    The laser synchronizing detection signal for the end position of LDB [K], [Y], [M], [C] is not detected for one second after the LDB unit turned on when detecting the main scan magnification
  • Causes: Disconnected or defective harness to synchronizing detector for end position. Defective synchronizing detector board. Defective LD board or driver. Defective BICU.
  • Remedy: 1. Replace the harness of the LD board. 2. Replace the laser optics housing unit. 3. Replace the BICU.
  • Code: 211
  • Description: Laser synchronizing detection error: end position [Y]
    The laser synchronizing detection signal for the end position of LDB [K], [Y], [M], [C] is not detected for one second after the LDB unit turned on when detecting the main scan magnification
  • Causes: Disconnected or defective harness to synchronizing detector for end position. Defective synchronizing detector board. Defective LD board or driver. Defective BICU.
  • Remedy: 1. Replace the harness of the LD board. 2. Replace the laser optics housing unit. 3. Replace the BICU.