Causes: [6101] MAC address check sum error The result of the MAC address check sum does not match the check sum stored in ROM. [6104] PHY IC error The PHY IC on the controller cannot be correctly recognized. [6105] PHY IC loop-back error An error occurred during the loop-back test for the PHY IC on the controller. - Replace the controller.
Description: [1401] Self-diagnosis error: Standard NVRAM The controller cannot recognize the standard NVRAM installed or detects that the NVRAM is defective.
Causes: [1501] The one second counted by the RTC is different from the one second counted by the CPU on the i-controller. • Defective the RTC device Replace the RTC device.. [15FF] The RTC device is not detected. • Defective RTC device • NVRAM without RTC installed • Discharged backup battery Replace the NVRAM with another NVRAM with an RTC device.
Description: Self-diagnostic error: Standard SDRAM DIMM [XXXX]: Detailed error code
Causes: [0201] Verification error Error detected during a write/verify check for the standard RAM (SDRAM DIMM). • Loose connection • Defective SDRAM DIMM • Defective controller 1. Turn the main switch off and on. 2. Replace the SDRAM DIMM. 3. Replace the controller. [0202] Resident memory error The SPD values in all RAM DIMM are incorrect or unreadable. • Defective RAM DIMM • Defective SPD ROM on RAM DIMM • Defective 12C bus 1. Replace the RAM DIMM.
Description: Self-diagnostic error: ROM [XXXX]: Detailed error code
Causes: [0101] Check sum error 1 • The boot monitor and OS program stored in the ROM DIMM is checked. If the check sum of the program is incorrect, this SC code is displayed.
Causes: [0401] Verification error (Slot 1) The data stored in the optional RAM in Slot 1 does not match the data when reading. • Not specified RAM DIMM installed • Defective RAM DIMM
Remedy: 1. Replace the RAM DIMM. 2. Replace the controller board.
Causes: [0F30] [0F31] • ASIC (Mandolin) for system control could not be detected. After the PCI configuration, the device ID for the ASIC could not be checked. Replace the VBCU [0F41] • ASIC (Mandolin) for system control could not be detected. After the PCI configuration, the device ID for the ASIC could not be checked. Replace the VBCU [50B1] Could not initialize or read the bus connection. • Check for loose connections at the mother board. Replace the mother board [50B2] Value of the SSCG register is incorrect. • Check for loose connections at the mother board. Replace the mother board
Causes: [9101] The ID of the USB NAND Flash ROM cannot be read. • Defective i-controller board Replace the i-controller board. [9110] The USB NAND Flash ROM is disconnected. • Defective i-controller board Replace the i-controller board.
Remedy:
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.