Description: Tray 2 lift motor malfunction (Optional paper tray unit)
The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for
18 seconds.
Causes: • Paper lift sensor defective
• Tray lift motor defective
• Too much load on the drive mechanism
• Poor tray lift motor connection
Code: 503
Description: Tray 3 lift motor malfunction (optional paper tray unit)
The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds.
Causes: • Paper lift sensor defective
• Tray lift motor defective
• Too much load on the drive mechanism
• Poor tray lift motor connection
Code: 506
Description: Paper feed motor lock (optional paper tray unit)
A motor lock signal is not detected for more than 1.5 s or the lock signal is not detected for more than 1.0 s during rotation.
Causes: • Paper feed motor defective
• Too much load on the drive mechanism
Code: 541
Description: Fusing thermistor open (center)
The fusing temperature detected by the thermistor is below 71°C and is not corrected after the main power switch is turned on.
Causes: • Fusing thermistor defective or out of position
• Power supply board defective
• Loose connectors
Code: 542
Description: Fusing temperature warm-up error (center)
The fusing temperature rises less than 9 degrees in 3 seconds, and this continues 5 times consecutively. The fusing temperature is not detected in 90 seconds after turning on the fusing lamp.
Causes: • Fusing thermistor defective or out of position
• Fusing lamp open
• Power supply board defective
Code: 543
Description: Fusing overheat error (center)
The fusing temperature is over 230°C and continues 10 times consecutively. (100ms x 10 = 1
second). (detected by the thermistor).
Causes: • Fusing thermistor defective
• Power supply board defective
Code: 544
Description: Fusing overheat error (center) 2
The fusing temperature is over 250°C and continues 10 times consecutively. (100ms x 10 = 1 second). (detected by the fusing temperature monitor circuit).
Causes: • Fusing thermistor defective
• Power supply board defective
Code: 545
Description: Fusing lamp overheat error (center)
After the fusing temperature reaches the target temperature, the fusing lamp does not turn off for 15 consecutive seconds.
Causes: • Fusing thermistor defective or out of position
• Power supply board defective