Các lỗi thường gặp

Code :
  • Code: 502
  • Description: Tray 2 lift motor malfunction (Optional paper tray unit)
    The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for
    18 seconds.
  • Causes: • Paper lift sensor defective
    • Tray lift motor defective
    • Too much load on the drive mechanism
    • Poor tray lift motor connection
  • Code: 503
  • Description: Tray 3 lift motor malfunction (optional paper tray unit)
    The paper lift sensor fails to activate twice continuously after the tray lift motor has been on for 18 seconds.
  • Causes: • Paper lift sensor defective
    • Tray lift motor defective
    • Too much load on the drive mechanism
    • Poor tray lift motor connection
  • Code: 506
  • Description: Paper feed motor lock (optional paper tray unit)
    A motor lock signal is not detected for more than 1.5 s or the lock signal is not detected for more than 1.0 s during rotation.
  • Causes: • Paper feed motor defective
    • Too much load on the drive mechanism
  • Code: 541
  • Description: Fusing thermistor open (center)
    The fusing temperature detected by the thermistor is below 71°C and is not corrected after the main power switch is turned on.
  • Causes: • Fusing thermistor defective or out of position
    • Power supply board defective
    • Loose connectors
  • Code: 542
  • Description: Fusing temperature warm-up error (center)
    The fusing temperature rises less than 9 degrees in 3 seconds, and this continues 5 times consecutively. The fusing temperature is not detected in 90 seconds after turning on the fusing lamp.
  • Causes: • Fusing thermistor defective or out of position
    • Fusing lamp open
    • Power supply board defective
  • Code: 543
  • Description: Fusing overheat error (center)
    The fusing temperature is over 230°C and continues 10 times consecutively. (100ms x 10 = 1
    second). (detected by the thermistor).
  • Causes: • Fusing thermistor defective
    • Power supply board defective
  • Code: 544
  • Description: Fusing overheat error (center) 2
    The fusing temperature is over 250°C and continues 10 times consecutively. (100ms x 10 = 1 second). (detected by the fusing temperature monitor circuit).
  • Causes: • Fusing thermistor defective
    • Power supply board defective
  • Code: 545
  • Description: Fusing lamp overheat error (center)
    After the fusing temperature reaches the target temperature, the fusing lamp does not turn off for 15 consecutive seconds.
  • Causes: • Fusing thermistor defective or out of position
    • Power supply board defective