Các lỗi thường gặp

Code :
  • Code: 101
  • Description: Exposure Lamp Error
    The scanner has scanned the white plate, but cannot detect the white level.
  • Causes: • Defective exposure lamp
    • Defective exposure lamp stabilizer
    • Defective exposure lamp connector
    • Unclean scanner mirror
    • Scanner mirror out of position
    • Defective SBU board
    • Defective SBU connector
    • Lens block out of position
    • Incorrect position or width of white plate scanning (* SP4-015)
  • Code: 120
  • Description: Scanner home position error 1
    The scanner home position sensor does not detect the scanner leaving the home position.
  • Causes: • Defective scanner home position sensor
    • Defective scanner drive motor
    • Defective scanner home position sensor connector
    • Defective scanner drive motor connector
    • Defective BICU board
  • Code: 121
  • Description: Scanner home position error 2
    The scanner home position sensor does not detect the scanner coming back to the home position.
  • Causes: • Defective scanner home position sensor
    • Defective scanner drive motor
    • Defective scanner home position sensor connector
    • Defective scanner drive motor connector
    • Defective BICU board
  • Code: 141
  • Description: SBU black level correction error
    • The automatic SBU adjustment has failed to correct the black level three times at the pre-offset adjustment.
    • The automatic SBU adjustment has failed to correct the black level ten times at the PGA adjustment.
    • The automatic SBU adjustment has failed to correct the black level ten times at the offset adjustment.
  • Causes: • Defective SBU board
  • Code: 142
  • Description: SBU white/black level correction error
    The automatic SBU adjustment has failed to correct the white level ten times at the PGA adjustment.
  • Causes: • Defective exposure lamp
    • Unclean white plate
    • Incorrect position or width of white plate scanning (* SP4-015)
    • Defective SBU board
  • Code: 144
  • Description: Communication Error between BICU and SBU
    The BICU cannot correctly establish communication with the SBU.
  • Causes: • Loose connection of the flat cable between the BICU and the SBU
    • Defective flat cable between the BICU and the SBU
    • Defective BICU
    • Defective SBU
  • Code: 145
  • Description: Automatic SBU adjustment error
    The white levels of the white plate and the white paper are extraordinarily different during the Scan Auto Adjustment (* SP4-428-001).
  • Causes: • Defective exposure lamp
    • Unclean white plate
    • Incorrect position or width of white plate scanning (* SP4-015)
    • Defective BICU board
    • Defective SBU board
  • Code: 193
  • Description: Image transfer error
    Scanned images are not transferred to the controller memory within one minute.
  • Causes: • Defective BICU board
    • Defective controller board