Description: Key/card counter device error 1
After 1 data frame is sent to the device, an ACK signal is not received within 100 ms, and is not received after 3 retries.
Causes: • The serial line from the device to the copier is unstable, disconnected, or defective.
Code: 633
Description: Key/card counter device error 2
During communication with the device, the BCU received a break (Low) signal.
Causes: • The serial line from the device to the copier is unstable, disconnected, or defective.
Code: 634
Description: Key/card counter device error 3
The backup battery of the counter device RAM is low.
Causes: • Replace the RAM backup battery.
Code: 635
Description: Key/card counter device error 4
After installation of the device a message alerts user to a battery voltage abnormal error.
Causes: • Device control board defective • Device control board backup battery defective
Code: 640
Description: BICU-to-Controller Data Transfer Error 1: Sum Check Error
The system detected an error during sum check for data transfer from the BICU to the controller board. Note: This error is simply logged and the machine does not return an error number on the display.
Causes: • No action required • The log count increments by one for every error
Code: 641
Description: BICU-to-Controller Data Transfer Error 2: Frame Error
The system detected an error after data was sent from the BICU to the controller board.
Causes: • No action required • The log count increments by one for every error
Code: 670
Description: Engine startup error
The BCU failed to respond with the prescribed time when the machine was turned on.
Causes: • Connections between BCU and controller board are loose, disconnected, or damaged • Replace the BCU • Replace the controller board
Code: 672
Description: Controller startup error
• After power on, the line between the controller and the operation panel did not open for normal operation. • After normal startup, communication with the controller stopped.