Description: Clamper Motor Failure The MPU cannot detect the clamper position sensor signal (open or closed) within 3.0 seconds after the clamper motor turns on.
Causes: Clamper drive Clamper sensors Clamper motor MPU board Main motor encoder Master eject position sensor
Code: E-01
Description: Cutter error The cutter HP sensor does not turn on within 3.0 seconds after the cutter motor turns on.
Causes: Cutter drive Cutter switch Cutter motor
Code: E-02
Description: Paper Table Drive error The paper height sensor or the table lower limit sensor does not turn on within 7.5 seconds after the table motor turns on. Paper height sensor 1 or 2 does not turn on within 1 second after the paper height sensor 1 or 2 turn on.
Causes: Paper table drive Paper table motor Paper height sensor 1 or 2 Paper table lower limit sensor Gears Paper table spring
Code: E-04
Description: Thermal Head Overheat Temperature of the thermal head is greater than 65°C when the Start key is pressed.
Causes: Overheat (wait for the thermal head to cool down) Thermal head
Code: E-06
Description: Main Motor Lock The CPU cannot detect the master eject position sensor (drum HP) signal within 5.0 seconds after the main motor turns on.
Causes: Main motor drive Main motor Motor drive board Master eject position sensor
Code: E-09
Description: Thermal Head Thermistor Open The thermistor output voltage is over 4.432 volts.
Causes: Thermal head thermistor Thermal head connector
Code: E-10
Description: Thermal Head Energy Pulse error The CPU detects an abnormal ID signal from the thermal head energy control pulse.
Causes: Thermal head connector Thermal head MPU
Code: E-12
Description: Pressure Plate error The pressure plate home position sensor does not turn on within 6 seconds during initialization. Both the pressure plate home position and pressure plate limit sensors turn on when the main SW is turned on. The pressure plate home position sensor does not turn off when the pressure plate limit sensor does not turn on within 4.5 seconds when compressing the ejected master.
Causes: Pressure plate drive Pressure plate motor Plate position sensors Master eject error