Mã lỗi Ricoh D040 MPC2550 DI-C1 — Trang 13/23

Code: 611

Description: Mechanical counter error: FC
This SC is only for NA models. The machine detects the mechanical counter error when SP5987-001 is set to "1".
Causes: • Disconnected mechanical counter • Defective mechanical counter
Remedy: 1. Check or replace the mechanical counter. 2. Replace the BCU.

Code: 620

Description: ARDF communication error
After the ARDF is detected, the break signal occurs or communication timeout occurs.
Causes: • Incorrect installation of ARDF • ARDF defective • BICU board defective • External noise
Remedy: 1. Check the cable connection of the ARDF. 2. Shut out the external noise. 3. Replace the ARDF. 4. Replace the BCU board.

Code: 621

Description: Finisher communication error
While the IOB communicates with an optional unit, an SC code is displayed if one of following conditions occurs. • The IOB receives the break signal which is generated by the peripherals only just after the main switch is turned on. • When the IOB does not receive an OK signal from a peripheral 100ms after sending a command to it. The IOB resends the command. The IOB does not receive an OK signal after sending the command 3 times.
Causes: • Cable problems • IOB problems • BICU problems • PSU problems in the machine • Main board problems in the peripherals
Remedy: 1. Check if the cables of peripherals are correctly connected. 2. Replace the PSU if no power is supplied to peripherals. 3. Replace the main board of peripherals. 4. Replace the BCU.

Code: 632

Description: Counter device error 1
After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms.
Causes: • Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged • Make sure that SP5113 is set to enable the optional counter device.
Remedy:

Code: 633

Description: Counter device error 2
After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms.
Causes: • Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged • Make sure that SP5113 is set to enable the optional counter device.
Remedy:

Code: 634

Description: Counter device error 3
A backup RAM error was returned by the counter device.
Causes: • Counter device control board defective • Backup battery of counter device defective
Remedy:

Code: 635

Description: Counter device error 4
A backup battery error was returned by the counter device.
Causes: • Counter device control board defective • Backup battery of counter device defective
Remedy:

Code: 636

Description: SD Card Error
Causes: 01 D Expanded authentication module error There is no expanded authentication module in the machine. The SD card or the file of the expanded authentication module is broken. There is no DESS module in the machine. • No expanded authentication module • Defective SD card • No DESS module 02 D Version error The version of the expanded authentication module is not correct. • Incorrect module version 1. Install the correct file of the expanded authentication module.
Remedy: 1. Install the expanded authentication module. 2. Install the SD card. 3. Install the DESS module.