Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Ricoh D081 MPC6501 V-C3 — Trang 2/44

Code: SC161

Description: IPU error
Communication error between IPU, SBU, and VBCU.
Causes: • Check harness connections between SBU and IPU/VBCU • IPU defective • VBCU defective

Code: SC161-1

Description: An error occurred when the ASIC executed a self-diagnostic report on the BICU.
Causes: • Defective BICU • Defective connection between BICU and SBU

Code: SC161-2

Description: The machine detects an error during an access to the Ri.
Causes: • Defective BICU board

Code: SC161-3

Description: The IPU fails to configure or initialize the DRAM.
Causes: • Defective BICU board

Code: SC165

Description: Illegal Copy Prevention Error
An abnormality was detected with the ICIB board at power on.
Causes: • ICIB connected incorrectly • ICIB defective

Code: SC180

Description: Scanner fan lock The fan motor next to the SIOB did not switch on within 10 sec. after the CPU issued the ON signal.
Causes: • Fan defective • Foreign object interfering with operation of fan • Motor harness loose, disconnected, or broken • SIOB defective

Code: SC181

Description: Scanner Fan Error: Lamp Stabilizer
The exposure lamp regulator fan is not rotating.
Causes: • Check the fan connections • Fan defective • Check SBU connection • Check SIOB connection • SBU defective • SIOB defective

Code: SC182

Description: Scanner Fan Error: Right Side
The fan located on the right side of the exposure unit is not rotating.
Causes: • Check the fan connections • Fan defective • Check SBU connection • Check SIOB connection • SBU defective • SIOB defective