Causes: An unexpected error occurred when the modem (Cumin-M) tried to call the center with a dial up connection due to: • Program parameter error (001) • Program execution error (002).
Remedy: • Software bug • No action required because this SC does not interfere with operation of the machine.
Description: @Remote Service ID2 Mismatch Error 1 CTL ID2 for the device did not match the ID2 stored in NVRAM. This error can occur if the controller has been replaced with the Cumin ID2 set for another machine, or if the NVRAM has been replaced with the NVRAM from another machine.
Causes: • If this error occurs when Cumin is set up, check the Cumin documentation and make sure that the NVRAM is compatible, set the common authentication, then try again.. • If this error occurs after Cumin has been set, clear the Cumin setting, check the Cumin documentation and make sure that the NVRAM is compatible, set the common authentication, then try again.
Causes: One of the following problems exist with the ID2 stored in NVRAM: • ID2 has less than 17 digits • A non-printable character exists in ID2 • ID2 is all spaces • ID2 is NULL
Remedy: • Replace NVRAM. • Clear the Cumin setting, set the common authentication, then try again.