Code: 877

Description: HDD Data Overwrite Security SD card error
The 'all delete' function cannot be executed but the Data Overwrite Security Unit (D377) is installed and activated.
Causes: • Defective SD card (D377) • SD card (D377) not installed
Remedy: 1. Replace the NVRAM and then install the new SD card (D362). 2. Check and reinstall the SD card (D362).

Code: 878

Description: TPM system authentication error
The system firmware is not authenticated by TPM (security chip).
Causes: • Incorrect updating for the system firmware • Defective flash ROM on the controller board
Remedy: Replace the controller board.

Code: 880

Description: File format converter error
The file format converter does not respond.
Causes: • Defective file format converter
Remedy: Replace the file format converter.

Code: 900

Description: Electric counter error
Abnormal data in the counters.
Causes: • Defective NVRAM • Defective controller
Remedy: 1. Check the connection between the NVRAM and controller. 2. Replace the NVRAM. 3. Replace the controller.

Code: 920

Description: Printer application error An error is detected in the printer application program.
Causes: • Defective software • Unexpected hardware resource (e.g., memory shortage)
Remedy: 1. Software defective; switch off/on, or change the controller firmware if the problem is not solved 2. Insufficient memory

Code: 921

Description: Printer font error
A necessary font is not found in the SD card.
Causes: • A necessary font is not found in the SD card. • The SD card data is corrupted.
Remedy: Check that the SD card has the correct data.

Code: 990

Description: Software performance error
The software makes an unexpected operation.
Causes: • Defective software • Defective controller • Software error
Remedy: 1. Turn the main switch off and on. 2. Reinstall the controller and/or engine main firmware. • See Note 1 at the end of the SC table.

Code: 991

Description: Software continuity error
The software has attempted to perform an unexpected operation. However, unlike SC 990, the object of the error is continuity of the software.
Causes: • Software program error • Internal parameter incorrect, insufficient working memory.