Các lỗi thường gặp

Code :
  • Code: 562-03
  • Description: Heating roller warm-up error (sensor 3)
    The center temperature of the heating roller does not reach the target reload permit pressure within the prescribed time.
  • Causes: Dirty thermopile lenses. Defective heating roller thermistor. Input voltage out of the warranty (out of specification).
  • Remedy: 1. Check and clean the thermopile lenses. 2. Replace the thermopile 3. Replace the thermistor.
  • Code: 563
  • Description: Pressure roller overheat (software error): Center
    The temperature detected by the pressure roller thermistor stays at the prescribed temperature within the prescribed time.
  • Causes: Defective PSU. Defective BICU
  • Remedy: 1. Replace the PSU. 2. Replace the BICU.
  • Code: 564
  • Description: Pressure roller overheat (hardware error): Center
    The temperature detected by the pressure roller thermistor detects prescribed temperature.
  • Causes: Defective BICU. Defective fusing control system.
  • Remedy: 1. Replace the thermistor. 2. Replace the BICU.
  • Code: 571
  • Description: Pressure roller thermistor error: End
    The temperature detected by the pressure roller thermistor does not reach 0 °C within the prescribed time.
  • Causes: Loose connection of the pressure roller thermistor. Defective thermopile. Defective pressure roller thermistor.
  • Remedy: 1. Check if the pressure roller thermistor is firmly connected. 2. Replace the thermopile. 3. Replace the pressure roller thermistor.
  • Code: 572-03
  • Description: Heating roller warm-up error (sensor 4)
    The temperature of the heating roller does not reach 20 °C within the prescribed time.
  • Causes: Dirty thermopile lenses. Defective heating roller thermistor. Input voltage out of the warranty (out of specification).
  • Remedy: 1. Check and clean the thermopile lenses. 2. Replace the thermopile 3. Replace the thermistor.
  • Code: 573
  • Description: Pressure roller overheat (software error): End
    The temperature detected by the pressure roller thermistor stays at the prescribed temperature within the prescribed time.
  • Causes: Defective PSU. Defective BICU
  • Remedy: 1. Replace the PSU. 2. Replace the BICU.
  • Code: 574
  • Description: Pressure roller overheat (hardware error): End
    The temperature detected by the pressure roller thermistor detects prescribed temperature.
  • Causes: Defective BICU. Defective fusing control system
  • Remedy: 1. Replace the thermistor. 2. Replace the BICU.
  • Code: 610
  • Description: Mechanical counter error: Bk
    This SC is only for NA models. The machine detects the mechanical counter error when SP5987-001 is set to "1".
  • Causes: Disconnected mechanical counter. Defective mechanical counter.
  • Remedy: 1. Check or replace the mechanical counter.