Description: Self-diagnostic error: ASIC The Write & Verify check of the ASIC returned an error. Note: The main ASIC module on the controller board controls the bus of the ROM device.
Causes: [0B00] ASIC register check error A write-verify check occurred in the ASIC. • ASIC device • Controller board defective [0B06] ASIC detection error The I/O ASIC for system control was not detected. • Defective ASIC • Defective North Bridge and PCII/F • Controller board defective
Causes: [3003] HDD timeout Check performed only when HDD is installed: • HDD device was busy for over 31 seconds. • A diagnostic command was set for the HDD, but the device remained busy for over 6 seconds. • Defective HDD device • Defective HDD connector • Defective ASIC device • Replace or uninstall the HDD device. • Replace the HDD connector. • Replace the controller board. [3004] Diagnostics command error Diagnostic command issued an error. • Defective HDD device • Replace or remove the HDD device. [3013] HDD timeout (First machine) HDD device was busy for over 31 seconds, or Mandolin was not detected. A diagnostic command is set for the HDD, but the device remains was busy for over 6 seconds. • Defective HDD device • Defective HDD connector • Defective ASIC device • Replace or remove the HDD device. • Replace the HDD connector • Replace the controller board [3014] Diagnostics command error (First machine) Diagnostic command issued an error because Mandolin was not detected, or there was a w/r/c error in the HDD register • Defective HDD device • Replace the HDD device.
Causes: [6101] MAC address check sum error The result of the MAC address check sum did not match the check sum stored in ROM. • Defective SEEP ROM • Defective I2C bus (connection) • Replace the controller board [6104] PHY IC error The PHY IC on the controller was not recognized. • Defective PHY chip • Defective ASIC MII I/F • Replace the controller board [6105] PHY IC loop-back error An error occurred during the loop-back test for the PHY IC on the controller. • Defective PHY chip • Defective MAC of ASIC (SIMAC/COMIC/CELLO) • Defective I/F with the PHY board • Defective soldered connection on the PHY board • Replace the controller board
Causes: [0F30] ASIC (Mandolin) for engine control could not be detected. After the PCI was configured, the device ID for the ASIC could not be checked. • Defective ASIC (Mandolin) for system control • Defective North Bridge and AGPI/F • Replace the motherboard (engine I/F board). [50B1] Could not initialize or read the bus connection. • Defective connection bus • Defective SSCG • Replace the motherboard (engine I/F board). [50B2] SSCG register value was incorrect. • Defective connection bus • Defective SSCG • Replace the motherboard (engine I/F board).
Causes: [5101] An error occurred after write/verify check for optional RAM on the motherboard.. • Defective memory device • Replace the motherboard (engine I/F board).
Description: Self-diagnostic Error: Clock Generator A verify error occurred when setting data was read from the clock generator via the I2C bus.
Causes: [2701] A verify error occurred when setting data was read from the clock generator via the I2C bus • Defective clock generator • Defective I2C bus • Defective I2C port on the CPU • Replace the controller board.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.