Description: LCT Tray Error (Paper Overload Error): D709 During tray initialization, the upper limit sensor and the lower limit sensor were both on for 5 times consecutively.
Remedy: • Reduce loaded paper. • Replace or reconnect the upper limit sensor. • Replace or reconnect the lower limit sensor. • Replace the corresponding harness. • Replace the PCB.
Description: LCT Tray Error (Upper Limit Detection Error): D710 At the start of tray initialization, the upper limit sensor was detected as being off for 5 times before the pick-up solenoid was on.
Remedy: • Replace or reconnect the pick-up solenoid. • Replace or reconnect the upper limit sensor. • Replace the corresponding harness. • Replace the PCB.
Description: LCT Tray Error (Lift timeout): D710 During Tray initialization, the tray bottom plate was lifted but the upper limit sensor did not detect it after a specified time (27 seconds).
Causes: • Lift motor defective/connecter disconnected • Upper limit sensor defective/connecter disconnected • Related harness broken • PCB defective
Remedy: • Replace or reconnect the lift motor. • Replace or reconnect the upper limit sensor. • Replace the corresponding harness. • Replace the PCB.
Description: LCT Tray Error (front blower fan error): D710 Started LD signal check one second after LCT front blower fan became on and detected H level (abnormal) for 700 ms consecutively.
Causes: • Front blower fan defective/connecter disconnected • Related harness broken • PCB defective
Remedy: • Replace or reconnect the front blower fan. • Replace the corresponding harness. • Replace the PCB.
Description: LCT Tray Error (rear blower fan error): D710 Started LD signal check one second after LCT rear blower fan became on and detected H level (abnormal) for 700 ms consecutively.
Causes: • Rear blower fan defective/connecter disconnected • Related harness broken • PCB defective
Remedy: • Replace or reconnect the rear blower fan. • Replace the corresponding harness. • Replace the PCB.
Description: Bypass tray lift error The bottom plate started CW but the tray upper limit sensor did not become blocked within 3 seconds. If detected for the first or second time: User is instructed to set paper again. If detected for the third time: SC displayed The count of detections is reset when successful operation is detected and at power off/on.
Causes: • Bypass tray upper limit sensor defective/disconnected/harness broken • Bypass tray bottom plate lift motor defective/disconnected/harness broken • Circuit board (PFB) error • Bypass tray bottom plate/bottom plate drive unit does not move e.g. because physical obstacle (broken piece of the unit, etc.) is blocking operation.
Remedy: • Bypass tray bottom plate lift motor and bypass tray bottom plate upper limit sensor check/cleaning/replacement/harness reconnection/harness replacement • Check or replace the circuit board (PFB). • Check and/or replace the bypass tray bottom plate and bottom plate lift drive unit.
Description: Bypass tray lowering error The bottom plate started CCW but the tray upper limit sensor did not become non-blocked within 1.5 seconds. If detected for the first or second time: User is instructed to set paper again. If detected for the third time: SC displayed The count of detections is reset when successful operation is detected and at power off/on.
Causes: • Bypass tray upper limit sensor defective/disconnected/harness broken • Bypass tray bottom plate lift motor defective/disconnected/harness broken • Circuit board (PFB) error • Bypass tray bottom plate/bottom plate drive unit does not move e.g. because physical obstacle (broken piece of the unit, etc.) is blocking operation.
Remedy: • Bypass tray bottom plate lift motor and bypass tray bottom plate upper limit sensor check/cleaning/replacement/harness reconnection/harness replacement • Check or replace the circuit board (PFB). • Check and/or replace the bypass tray bottom plate and bottom plate lift drive unit.
Description: Bypass tray lower limit error The bottom plate started CCW but the tray lower limit sensor did not become blocked within 3 seconds. If detected for the first or second time: User is instructed to set paper again. If detected for the third time: SC displayed The count of detections is reset when successful operation is detected and at power off/on.
Causes: • Bypass tray lower limit sensor defective/disconnected/harness broken • Bypass tray bottom plate lift motor defective/disconnected/harness broken • Circuit board (PFB) error • Bypass tray bottom plate/bottom plate drive unit does not move e.g. because physical obstacle (broken piece of the unit, etc.) is blocking operation.
Remedy: • Bypass tray bottom plate lift motor and bypass tray bottom plate lower limit sensor check/cleaning/replacement/harness reconnection/harness replacement • Check or replace the circuit board (PFB). • Check and/or replace the bypass tray bottom plate and bottom plate lift drive unit.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.