Description: Stacking Roller Drug Motor Error (D707) • When moving to the home position, home position was not detected within specified number of pulses (p0 pulses). (The first time: jam display, the second time: SC) • When moving from the home position, home position was still detected after specified number of pulses (p1 pulses). (The first time: jam display, the second time: SC)
Causes: • Overload due to staple jam or number of sheets exceeding the limit, etc. • Motor defective • Connecter disconnected • Home position sensor defective
Remedy: • Check the connections of the motor and home position sensor. • Replace the motor/home position sensor. • Replace the PCB.
Description: Downstream device communication error (D615) • Communication with the downstream device has established, but the device is not responding to the command sent out, even after being sent three times. • The port level of the downstream device does not become H level (break cancel) within specified time.
Description: Z-fold stopper 1 Motor error (D615) • When moving to the home position, home position was not detected within specified number of pulses (p0 pulses). (The first time: jam display, the second time: SC) • When moving from the home position, home position was still detected after specified number of pulses (p1 pulses). (The first time: jam display, the second time: SC) • Motor driver detected an error. (SC from the first time)
Causes: • Overcurrent to the motor. • Motor drive overheat • Connector disconnected
Remedy: • Replace the controller board. • Replace the motor. • Replace the harness. • Re-connect the connector. • Replace the sensor.
Description: 2nd Stopper Motor Error (D615) • When moving to the home position, home position was not detected within specified number of pulses (p0 pulses). (The first time: jam display, the second time: SC) • When moving from the home position, home position was still detected after specified number of pulses (p1 pulses). (The first time: jam display, the second time: SC) • Motor driver detected an error. (SC from the first time)
Causes: • Overcurrent to the motor. • Motor drive overheat • Connector disconnected
Remedy: • Replace the controller board. • Replace the motor. • Replace the harness. • Re-connect the connector. • Replace the sensor.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.