Mã lỗi Ricoh D136 MPC8002SP CH-C1 — Trang 20/63

Code: SC403-04

Description: Development Start Voltage (Vk) High Error (Y). Development Start Voltage (Vk) > 300 [-V] Details: This SC is issued when the development start voltage measured during process control exceeded 300[-V].
Causes: • Toner density error
Remedy: • Replace the developer.

Code: SC404-01

Description: Development Start Voltage (Vk) Low Error (K). Development Start Voltage (Vk) < 300 [-V] Details: This SC is issued when the development start voltage measured during process control was smaller than 300[-V].
Causes: • Toner density error • Condensation
Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.

Code: SC404-02

Description: Development Start Voltage (Vk) Low Error (C). Development Start Voltage (Vk) < 300 [-V] Details: This SC is issued when the development start voltage measured during process control was smaller than 300[-V].
Causes: • Toner density error • Condensation
Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.

Code: SC404-03

Description: Development Start Voltage (Vk) Low Error (M). Development Start Voltage (Vk) < 300 [-V] Details: This SC is issued when the development start voltage measured during process control was smaller than 300[-V].
Causes: • Toner density error • Condensation
Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.

Code: SC404-04

Description: Residual Voltage (Vr) Detection Error (K). Development Start Voltage (Vk) Low Error (Y). Development Start Voltage (Vk) < 300 [-V] Details: This SC is issued when the development start voltage measured during process control was smaller than 300[-V].
Causes: • Toner density error • Condensation
Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.

Code: SC410-01

Description: Residual Voltage (Vr) > 200[-V] Details: This SC is issued when the residual voltage measured duringprocess control exceeded 200 [-V].
Causes: • Toner density error • Condensation
Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.

Code: SC410-02

Description: Residual Voltage (Vr) Detection Error (C). Residual Voltage (Vr) > 200[-V] Details: This SC is issued when the residual voltage measured duringprocess control exceeded 200 [-V].
Causes: • Toner density error • Condensation
Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.

Code: SC410-03

Description: Residual Voltage (Vr) Detection Error (M). Residual Voltage (Vr) > 200[-V] Details: This SC is issued when the residual voltage measured duringprocess control exceeded 200 [-V].
Causes: • Toner density error • Condensation
Remedy: • Replace the developer. • If condensation has formed, wait a while and repeat process control.