Mã lỗi Ricoh D184 MP3353 OR-C2

Code: SC101-01

Description: Lamp Error (Scanning) The white level peak did not reach the prescribed threshold when the white plate was scanned.
Causes: • LED defective • IDB (LED driver) defective • SBU defective • IPU defective • Power/signal harness defective • Condensation in scanner unit • Mirrors or lenses dirty or positioned incorrectly • White plate dirty or installed incorrectly
Remedy: 1. Turn the power off/on. 2. Perform the following operations: • Reconnect the power/signal harness. • Reattach/clean the mirrors/lenses. • Reattach/clean the white plate. • Reattach/clean the scanner guide plate. 3. Replace the following parts: • Replace the LED board. • Replace the IDB board or SIO board. • Replace the SBU board. • Replace the IPU board. • Replace the power/signal harness.

Code: SC101-02

Description: Lamp Error (LED illumination adjustment) LED error was detected.
Causes: • LED defective • IDB (LED driver) defective • Power/signal harness defective
Remedy: 1. Turn the power off/on. 2. Perform the following operations: • Reconnect the power/signal harness. 3. Replace the following parts: • Replace the LED board. • Replace the IDB board or SIO board. • Replace the power/signal harness.

Code: SC102

Description: LED Illumination Adjustment Error The white level peak reached the prescribed threshold when the white plate was scanned after a specified number of adjustments.
Causes: • LED defective • IDB (LED driver) defective • SBU defective • IPU defective • Power/signal harness defective
Remedy: 1. Turn the power off/on. 2. Reconnect the power/signal harness. 3. Replace the following parts: • Replace the LED board. • Replace the SBU board. • Replace the IDB board or SIO board. • Replace the IPU board. • Replace the power/signal harness.

Code: SC120

Description: Scanner Home Position Error 1 The scanner home position sensor does not go OFF. Details: Error detection timing • During homing (when the machine is turned ON or when it returns from energy save mode) • During an automatic adjustment (when the machine is turned ON or when it returns from energy save mode) • During a scan from the ADF or exposure glass.
Causes: • Scanner motor driver defective • Scanner motor defective • Scanner HP sensor defective • Harness defective • Timing belt, pulley, wire, or carriage not installed correctly
Remedy: Replace the following parts: • Replace the HP sensor • Replace the scanner motor • Replace the harness.

Code: SC121

Description: Scanner Home Position Error 2 The scanner home position sensor does not go ON. Details: Error detection timing • During homing • During an automatic adjustment • During a scan from the ADF or exposure glass.
Causes: • Scanner motor driver defective • Scanner motor defective • Scanner HP sensor defective • Harness defective • Timing belt, pulley, wire, or carriage not installed correctly
Remedy: Replace the following parts: • Replace the home position sensor • Replace the scanner motor • Replace the harness.

Code: SC141

Description: Black level detection error The black level cannot be adjusted within the target during auto gain control.
Causes: • SBU defective • IPU defective • Power/signal harness defective
Remedy: 1. Turn the power off/on. 2. Reconnect the power/signal harness. 3. Replace the following parts: • Replace the SBU board. • Replace the IPU board. • Replace the power/signal harness.

Code: SC142

Description: White level detection error The white level cannot be adjusted to the second target level within the target during auto gain control.
Causes: • SBU defective • LED defective • IDB (LED driver) defective • IPU defective • Power/signal harness defective • Scanner drive error • Condensation in scanner unit • Mirrors or lenses dirty or positioned incorrectly • White plate dirty or installed incorrectly
Remedy: 1. Turn the power off/on. 2. Perform the following operations: • Reconnect the power/signal harness. • Reattach/clean the mirrors/lenses. • Reattach/clean the white plate. 3. Replace the following parts: • Replace the SBU board. • Replace the LED board. • Replace the IDB board. • Replace the IPU board. • Replace the SIO board. • Replace the power/signal harness.

Code: SC144

Description: SBU Communication Error • Connection to SBU cannot be confirmed. (Connection detection error) • Cannot communicate with the SBU, or the communication result is abnormal.
Causes: • SBU defective • The other side of the communication (BCU, IPU etc.) defective • Power/signal harness defective
Remedy: 1. Turn the power off/on. 2. Reconnect the power/signal harness. 3. Replace the following parts: • Replace the SBU board. • Replace the IPU board. • Replace the BCU board. • Replace the power/signal harness.