Các lỗi thường gặp

Code :
  • Code: 442
  • Description: Image transfer belt contact motor error The image transfer belt contact sensor does not detect the movement of actuator at the sensor while the polygon motor rotates.
  • Causes: • Dirty image transfer belt contact sensor • Defective image transfer belt contact motor • Disconnected connector of image transfer belt contact sensor or motor • Disconnected cable • Broken +24V fuse on PSU • Defective interlock switches • Defective BCU
  • Remedy: • Replace the image transfer belt contact sensor. • Replace the image transfer belt contact motor. • Replace the +24V fuse on the PSU. • Replace the interlock switches. • Replace the BCU.
  • Code: 443
  • Description: Image transfer unit error The machine detects the encoder sensor error.
  • Causes: • Defective encoder sensor • Image transfer unit installation error • Defective image transfer unit motor
  • Remedy: • Check if the image transfer unit is correctly set. • Replace the image transfer unit motor. • Replace the image transfer unit.
  • Code: 452
  • Description: Paper transfer unit contact error The paper transfer unit contact sensor does not detect the movement of actuator at the sensor while the polygon motor rotates.
  • Causes: • Defective paper transfer unit contact sensor • Defective paper transfer unit contact motor • Broken +24V fuse on PSU • Defective BCU
  • Remedy: • Check the connection between the paper transfer unit and PSU. • Replace the paper transfer unit contact sensor. • Replace the paper transfer unit contact motor. • Replace the +24V fuse on the PSU. • Replace the BCU.
  • Code: 460
  • Description: Separation power pack output error An interrupt checks the status of the power pack every 20 ms. This SC is issued if the BCU detects a short in the power pack 10 times at D(ac).
  • Causes: • Damaged insulation on the HVPS: D cable • Damaged insulation around the HVPS: D.
  • Remedy: • Replace the HVPS: D cable. • Replace the HVPS: D.
  • Code: 491
  • Description: High voltage power: Drum/ development bias output error An error signal is detected for 0.2 seconds when charging the drum or development.
  • Causes: • High voltage leak • Broken harness • Defective drum unit or development unit • Defective HVPS: CB
  • Remedy: • Check or replace the harness. • Replace the drum unit or paper transfer unit. • Replace the HVPS: CB.
  • Code: 492
  • Description: High voltage power: Image transfer/ paper transfer bias output error An error signal is detected for 0.2 seconds when charging the separation, image transfer bet or paper transfer roller.
  • Causes: • High voltage open • Broken harness • Defective image transfer belt unit or paper transfer unit • Defective HVPS: T1T2
  • Remedy: • Check or replace the harness. • Replace the image transfer belt unit or paper transfer unit. • Replace the HVPS: T1T2.
  • Code: 495
  • Description: Toner collection motor error The machine detects that the toner collection bottle is not set for one second when the toner collection motor is turned off.
  • Causes: • Toner collection motor damaged • Disconnect or defective harness
  • Remedy: • Check or replace the harness. • Replace the toner collection motor. • Check and retry the connecting procedure.
  • Code: 498
  • Description: Temperature and humidity sensor error • The thermistor output of the temperature sensor was not within the prescribed range (0.5V to 2.8V). • The thermistor output of the humidity sensor was not within the prescribed range (0.01V to 2.4V).
  • Causes: • Temperature and humidity sensor harness disconnected, loose, defective • Temperature and humidity sensor defective
  • Remedy: • Check the connector and harness. • Replace the temperature/humidity sensor.