Code: SC272-01

Description: LD Driver Communication Error If the value is not same when the machine reads and writes the same registration at the machine start-up. If the communication parity retries three consecutive times, the SC is generated.
Causes: • CPU defective • IPU defective • BCU defective • Harness defective
Remedy: • Cycle the main power off/on. • Replace the laser unit. • Replace the harness • Replace the IPU board

Code: SC272-10

Description: LD Driver Communication Error: Others If the “Door Open” status does not change to “Door Close” after closing the door.
Causes: • CPU defective • IPU defective • BCU defective • Harness defective
Remedy: • Cycle the main power off/on. • Replace the laser unit. • Replace the harness. • Replace the IPU board.

Code: SC302-00

Description: High Voltage Power Source: Charge: Output Error The machine detects the error detection signal “L (unexpected)” 10 times for 200 msec consecutively when monitoring the error signal every 20 msec during outputting the PWM signal.
Causes: Hardware error • Input / Output connector is disconnected. • Input / Output harness is short-circuited. • Surface/air clearance insufficient (arc discharge) • BCU error (signal error) • HVPS defective Load error • Grounding fault of charging output, short-circuit with other outputs • Surface/air clearance insufficient in charging output path (including distance from other outputs) • Unexpected deterioration of drum and over current due to pinholes gap error between the drum and charge roller (PCU error). • Over current due to drum surface condensation • PCU is disconnected.
Remedy: • Cycle the main power off/on. • Replace the high HVPS. • Replace the harness of the HVPS. • Replace the harness of the PCU. • Replace the PCU.

Code: SC324-01

Description: Development Motor: Bk: Lock Lock signals are observed at 2 sec intervals during motor ON, and a High level is detected at least 20 times
Causes: • Motor defective • Connector disconnected • Harness broken • IOB defective • Unit torque increased
Remedy: • Replace the development motor. • Reconnect the connector. • Replace the harness. • Replace the IOB. • Replace the development unit. • Replace the driven unit.

Code: SC360-01

Description: TD Sensor Adjustment Error • When Mu count exceeds the judgment threshold of no developer status. • When Mu count does not satisfy the following target ranges for 3 times in a row. • Upper threshold • Lower threshold
Causes: • TD sensor defective • Loose connection • Harness broken • Developer toner density differs from initial developer
Remedy: • Replace the TD sensor. • Replace the development unit.

Code: SC361-01

Description: TD Sensor Output Error: Upper Limit (K) The following condition continuously exceeds the upper limit threshold value (SP3-211-003). • TD sensor output: Vt (SP3-210-001) > output upper limit error threshold (SP3-211-002)
Causes: • TD sensor connector dropout (connection fault)
Remedy: • Check if the TD sensor connector is connected. • Check the harness of the TD sensor (disconnection, etc.). • Replace the TD sensor.

Code: SC362-01

Description: TD Sensor Output Error: Lower limit (K) TD sensor output: Vt (SP3-210-001) < output lower limit error threshold (SP3-211-004) is continuously below the lower limit occurrence threshold value (SP3-211-005)
Causes: TD sensor connector missing/dropout
Remedy: • Check if the TD sensor connector is connected. • Check the harness of the TD sensor (disconnection, etc.). • Replace the TD sensor.

Code: SC370-00

Description: ID Sensor Calibration Error Regular reflection optical output voltage of the ID sensor: Vsg_reg cannot be adjusted to within target range. Upper limit (SP3-320-013: initial value 4.5V) Lower limit (SP3-320-014: initial value 3.5V)
Causes: • ID sensor connector missing/ connection fault • ID sensor detection window dirt • ID sensor malfunction
Remedy: • Check for ID sensor connector missing. If it is missing, reconnect it. • Check for dirt on the ID sensor detection window. If the detection window is dirty, clean by predetermined method (do not wipe dry). • If neither of the above have occurred, perform ID sensor replacement.