Mã lỗi Ricoh D199 MP3354 Cor-C1 — Trang 11/40

Code: SC544-02

Description: Fusing High Temperature Detection (hardware) (Non-Contact thermistor High Temperature Error) In the event of an error
Causes: • Triac defective (short-circuit) • Engine controller defective • Heating central thermopile defective • Fusing control software: out of control
Remedy: • Attach the new fusing unit, then run SP-5-810-002. • If the triac is defective, replace the AC power supply board. • If necessary, replace the BCU or the Fusing central NC sensor.

Code: SC545-01

Description: Fusing Central Heater Continuously Heat After waiting for full power for more than specified seconds continuously, not detected for specified seconds. • Definition of heater full power Continuously heating rate set point (maximum heating rate) • Measurement start point After reload (after heater extinguished, after rotation complete) below the standby temperature (target temperature), measurement starts after a heater heat-up request is issued. • Measurement stop condition Rotation started due to a print signal during measurement or other. • Maximum heat-up Duty (SP interlinked value) 0% is excluded.
Causes: • Thermistor deformation/float • Heater disconnection • After excessive temperature rise prevention unit operates
Remedy: • Replace the thermistor. • Replace the fusing lamp. • Replace the fusing unit.

Code: SC545-05

Description: Fusing Central Heater Continuously Heat (Low Voltage)
Causes: Low Voltage
Remedy:

Code: SC547-01

Description: Zero cross Error (relay-contact soldering) In the event of an error
Causes: • Fusing relay defective (contact soldering) • Fusing relay drive circuit fault
Remedy: • Turn the main power supply switch OFF/ON • If the fusing relay is damaged, replace the PSU. • Check the connection between PSU and control board, and replace harness and board if necessary.

Code: SC547-02

Description: Zero cross Error (relay contact fault) In the event of an error
Causes: • Fusing relay damage (contact open) • Fusing relay drive circuit fault • PSU fuse (24VS) blowout
Remedy: • Turn the main power supply switch OFF/ON. • If the fusing relay is damaged, replace the PSU. • Check the connection between PSU and control board, and replace harness and board if necessary. • If the PSU fuse (24VS) blows out, replace the fuse.

Code: SC547-03

Description: Zero cross Error (low-frequency error) In the event of an error
Causes: Frequency instability of commercial power line
Remedy: • Turn the main power supply switch OFF/ON. • Check the power source. • Check the connection between PSU and control board, and replace harness and board if necessary.

Code: SC551-01

Description: Fusing Edge Thermopile Disconnection When the fusing edge thermopile detects a predetermined temperature or less for specified seconds consecutively.
Causes: • Thermopile disconnection • Connector disconnected
Remedy: • Replace the thermopile. • Reset the connector. • Replace the connector. • Replace the fusing unit.

Code: SC551-02

Description: Edge NC Sensor Disconnection 3ED - 3FF (FB voltage: 3.243V-3.300V) is detected for specified seconds continuously (NC sensor center: detection & compensation NC sensor edge: detection & compensation). Detection period: 100 ms, detection frequency: 10 times or more.
Causes: • NC sensor disconnection • Connector disconnected
Remedy: • Replace the NC sensor. • Reset the connector. • Replace the connector. • Replace the fusing unit.