Code: 651-02

Description: Illegal Remote Service Dial-up (Chat program execution error) An unexpected error occurred when RC Gate dialed up the NRS Center.
Causes: Software bug
Remedy: Logging only.

Code: 652-00

Description: Remote service ID2 mismatching There was an authentication mismatch between ID2 for @Remote, the controller board, and NVRAM.
Causes: • Used controller board installed • Used NVRAM installed (such action is not allowed.)
Remedy: • If this occurs during RC Gate installation: Check the validity of the certificate and the NVRAM, check the machine serial number, write the common certificate, and then begin installation again. • If this occurs after RC Gate installation: Clear the RC Gate install status, check the validity of the certificate and the NVRAM, check the machine serial number, write the common certificate, and then begin installation again.

Code: 653-00

Description: Incorrect remote service ID2 ID2 stored in the NVRAM has either of the following problems. • Number of characters is not 17. • Includes a character that cannot be printed. • All spaces • NULL
Causes: Replace the NVRAM.
Remedy: Clear the RC Gate install status, write the common certificate, and then begin installation again.

Code: 664-01

Description: ASIC – SRAM Communication error • When the machine starts or returns from the energy saver mode, a connection error signal between ASIC and SRAM device is detected.
Causes: • Defective BiCU
Remedy: • Cycle the power off/on. • Replace the BiCU.

Code: 665-05

Description: Master control signal connection error. When the machine starts or returns from the energy saver mode, a connection error signal between CPU and slave device is detected, or the machine cannot access all I/O IPU-ASICs correctly. SC665-11 through -031: When the machine starts or returns from the energy saver mode, a connection error between CPU and ASIC is detected.
Causes: 1. Incorrect FFC connection 2. Damaged FFC (disconnection or dust) 3. BiCU failure (Deteriorated board, sticking dust, or damaged parts)
Remedy: • Cycle the power off/on. • Replace the BiCU.

Code: 665-06

Description: IPU/IOB control signal connection error. When the machine starts or returns from the energy saver mode, a connection error signal between CPU and slave device is detected, or the machine cannot access all I/O IPU-ASICs correctly. SC665-11 through -031: When the machine starts or returns from the energy saver mode, a connection error between CPU and ASIC is detected.
Causes: 1. Incorrect FFC connection 2. Damaged FFC (disconnection or dust) 3. BiCU failure (Deteriorated board, sticking dust, or damaged parts)
Remedy: • Cycle the power off/on. • Replace the BiCU.

Code: 665-07

Description: IPU control signal connection error. When the machine starts or returns from the energy saver mode, a connection error signal between CPU and slave device is detected, or the machine cannot access all I/O IPU-ASICs correctly. SC665-11 through -031: When the machine starts or returns from the energy saver mode, a connection error between CPU and ASIC is detected.
Causes: 1. Incorrect FFC connection 2. Damaged FFC (disconnection or dust) 3. BiCU failure (Deteriorated board, sticking dust, or damaged parts)
Remedy: • Cycle the power off/on. • Replace the BiCU.

Code: 665-11

Description: ASIC connection error. When the machine starts or returns from the energy saver mode, a connection error signal between CPU and slave device is detected, or the machine cannot access all I/O IPU-ASICs correctly. SC665-11 through -031: When the machine starts or returns from the energy saver mode, a connection error between CPU and ASIC is detected.
Causes: 1. Incorrect FFC connection 2. Damaged FFC (disconnection or dust) 3. BiCU failure (Deteriorated board, sticking dust, or damaged parts)
Remedy: • Cycle the power off/on. • Replace the BiCU.