Các lỗi thường gặp

Code :
  • Code: SC564-00
  • Description: Fusing High Temperature Detection (hardware) (Pressure Roller Thermistor Error) In the event of an error
  • Causes: • Triac short-circuit • Pressure roller thermistor defective • BCU controller defective • Fusing control: out of control
  • Remedy: • Replace the BCU. • Replace the pressure roller thermistor. • Replace the fusing unit.
  • Code: SC571-00
  • Description: Pressurized Edge Thermistor Disconnection When the pressurized edge thermistor detects a predetermined temperature or less for specified seconds consecutively. Detection period: 100 ms, detection counts: 10 times or more.
  • Causes: • Thermistor disconnection • Connector disconnected
  • Remedy: • Replace the thermistor. • Reset the connector. • Replace the connector. • Replace the fusing unit.
  • Code: SC572-02
  • Description: Pressurized Edge Thermistor Does Not Reload When the temperature does not reach 40 degrees Centigrade for 100 seconds consecutively.
  • Causes: • Thermistor dirt • Thermistor deformation, float • Outside input voltage guarantee • After excess temperature rise prevention unit operation
  • Remedy: • Replace the thermistor. • Make sure that the input voltage is within acceptable limits. • Replace the fusing unit.
  • Code: SC573-00
  • Description: Pressurized Edge Thermistor High Temperature Detection (software) When the pressurized edge thermistor detects a predetermined temperature or above for specified second consecutively.
  • Causes: • Triac short-circuit • IOB defective • BCU defective
  • Remedy: • Replace the IOB. • Replace the BCU. • Replace the fusing unit.
  • Code: SC574-00
  • Description: Pressurized Edge Thermistor High Temperature Detection (hardware) Above a predetermined temperature detected
  • Causes: • Triac short-circuit • Pressure roller thermistor defective • BCU defective • Fusing control: out of control
  • Remedy: • Replace the BCU. • Replace the pressure roller thermistor. • Replace the fusing unit.
  • Code: SC589-01
  • Description: Fusing center: Low Temperature Detection When the fusing center thermopile detects the temperature which is 180 degrees Centigrade lower than target Temperature for 12 seconds consecutively.
  • Causes: • Heater harness disconnected • Connector defective
  • Remedy: • Replace the Heater harness. • Replace the connector.
  • Code: SC589-02
  • Description: Fusing edge: Low Temperature Detection When the fusing edge thermopile detects the temperature which is 180 degrees Centigrade lower than target Temperature for 12 seconds consecutively.
  • Causes: • Heater harness disconnected • Connector defective
  • Remedy: • Replace the Heater harness. • Replace the connector.
  • Code: SC620-01
  • Description: ADF Communication Error. After ADF connection was recognized on startup, an error is detected. (disconnection detection)
  • Causes: • ADF connection fault • ADF defection • IPU board defection • Noise contamination • ADF machine code unmatched
  • Remedy: • Check the ADF cable connection • Replace the ADF • Replace the IPU board • Replace the ADF which matches the machine code