Description: Clamper Motor Failure The MPU cannot detect the clamper position sensor signal (open or closed) within 3.0 seconds after the clamper motor turns on.
Causes: Clamper drive Clamper sensors Clamper motor MPU board Main motor encoder Master eject position sensor
Description: Paper Table Drive error: The paper height sensor or the table lower limit sensor does not turn on within 7.5 seconds after the table motor turns on. Paper height sensor 1 or 2 does not turn on within 1 second after the paper height sensor 1 or 2 turn on.
Causes: Paper table drive Paper table motor Paper height sensor 1 or 2 Paper table lower limit sensor Gears Paper table spring
Description: Main Motor Lock: The CPU cannot detect the master eject position sensor (drum HP) signal within 5.0 seconds after the main motor turns on.
Causes: Main motor drive Main motor Motor drive board Master eject position sensor
Description: Pressure Plate error: The pressure plate home position sensor does not turn on within 6 seconds during initialization. Both the pressure plate home position and pressure plate limit sensors turn on when the main SW is turned on. The pressure plate home position sensor does not turn off when the pressure plate limit sensor does not turn on within 4.5 seconds when compressing the ejected master.
Causes: Pressure plate drive Pressure plate motor Plate position sensors Master eject error
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.