Các lỗi thường gặp

Code :
  • Code: E-41
  • Description: Idling roller HP sensor remains on or off The idling roller HP sensor does not change status within 4.0 seconds after the idling roller motor on signal is generated.
  • Causes: Idling roller HP sensor Ink idling motor
  • Code: E-42
  • Description: Duct plate error The duct plate HP sensor does not change status within 4.0 seconds after the duct plate motor on signal is generated.
  • Causes: Duct plate HP sensor Duct plate motor
  • Code: E-43
  • Description: Printing Pressure error The printing pressure HP sensor does not change status within 4.0 seconds after the printing pressure motor on signal is generated.
  • Causes: Printing pressure HP sensor Printing pressure motor
  • Code: E-47
  • Description: Thermal head driving error The thermal head HP sensor does not change status within 4.0 seconds after the thermal head driving motor on signal is generated.
  • Causes: Thermal head HP sensor Thermal head driving motor
  • Code: E-61
  • Description: Auto Off Switch error The main switch does not turn off for more than 6.0 seconds.
  • Causes: Auto off switch Auto off switch connector disconnected