Description: Paper transfer negative bias open The PWM duty has been 50% or greater for 240 ms.
Causes: There is disconnection in the paper transfer bias supply circuit. (Dirty or deformed electrodes)
Code: 48
Description: Paper transfer negative current error A/D converted voltage has been 4.8 V or more for 240 ms.
Causes: There is a short circuit in the paper transfer bias supply circuit (due to deformed terminals or electrodes or conductive foreign matter)
Code: 49
Description: Pressure roller reheat timeout When reheating, the roller temperature does not reach the reheat start temperature (target temperature -20°C) within five minutes.
Description: Hot roller reheat timeout When reheating, the roller temperature does not reach the reheat start temperature (target temperature -10°C) within five minutes.
Causes: Hot roller thermistor, hot roller lamp connector, MCU
Code: 51
Description: Pressure roller lamp full-power operation error When full-power operation occurs during reheating, the main motor is not running and the difference between the current temperature and that of 60 seconds ago is 18°C or less.
Description: Hot roller lamp fullpower operation error When full-power operation occurs during reheating, the main motor is not running and the difference between the current temperature and that of 60 seconds ago is 18°C or less.
Causes: Hot roller thermistor, hot roller lamp connector, MCU
Code: 57
Description: Print command error When an abnormal combination of print commands is received.
Causes:
Code: 59
Description: Temperature sensor error 5 V (4.75 V) or more has continuously been detected for five seconds.