Description: EEPROM error The main switch is turned on.- EEPROM is not connected.
Causes: • Incorrect EEPROM connection
Code: 687
Description: PER command error . Some image data is transferred. - The controller does not report the necessary memory address. . The PES command is issued. - The controller does not issue the necessary memory report (PER) command within 6 seconds.
Causes: • Poor connection between BCU and controller • Defective BCU • Defective controller
Code: 730
Description: Four-bin mail box communication error • A connection error occurs. • The UART reports a communication error. • In other cases than paper transport, after an every-3- second command is sent, the mail box does not respond within 5 seconds.
Causes: • Defective mail box control board • Defective BCU • Defective IOB • Incorrect installation
Code: 740
Description: Finisher communication error • A connection error occurs. • The UART reports a communication error. • In other cases than paper transport, after an every-3- second command is sent, the finisher does not respond within 5 seconds.