Các lỗi thường gặp

Code :
  • Code: 531
  • Description: Optics unit fan error
  • Causes: • Loose connection • Defective fan • Defective input output device • Defective BCU
  • Code: 532
  • Description: Fusing fan error
  • Causes: • Loose connection • Defective fan • Defective input output device • Defective BCU
  • Code: 540
  • Description: Scanner motor error
  • Causes: • Loose connection • Defective LD unit • Defective BCU
  • Code: 541
  • Description: Thermistor short-circuit error
  • Causes: • Loose connection • Incorrect installation of the fusing unit • Defective fusing unit • Defective BCU
  • Code: 542
  • Description: Fusing lamp error
  • Causes: • Loose connection • Defective thermistor • Defective fusing unit • Defective power supply unit • Defective BCU • Insufficient power supply
  • Code: 543
  • Description: Fusing temperature error during warming up
  • Causes: • Loose connection • Defective thermistor • Defective fusing unit • Defective power supply unit • Defective BCU • Insufficient power supply
  • Code: 544
  • Description: Fusing temperature error during on
  • Causes: • Loose connection • Defective thermistor • Defective fusing unit • Defective power supply unit • Defective BCU • Insufficient power supply
  • Code: 545
  • Description: Fusing temperature error during off
  • Causes: • Loose connection • Defective thermistor • Defective fusing unit • Defective power supply unit • Defective BCU • Insufficient power supply
 < 1 2 3 4 5 6 7 >  Last ›