Description: TD sensor [K]: Adjustment error During the developer initialization, the output value of the TD sensor is without the adjustment range (3.0 ± 0.1V).
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Remedy: 1. Turn the main switch off and on. 2. Reset the related color development unit. 3. Replace the related color development unit.
Code: SC 371
Description: TD sensor [Y]: Adjustment error During the developer initialization, the output value of the TD sensor is without the adjustment range (3.0 ± 0.1V).
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Remedy: 1. Turn the main switch off and on. 2. Reset the related color development unit. 3. Replace the related color development unit.
Code: SC 372
Description: TD sensor [C]: Adjustment erro rDuring the developer initialization, the output value of the TD sensor is without the adjustment range (3.0 ± 0.1V).
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Remedy: 1. Turn the main switch off and on. 2. Reset the related color development unit. 3. Replace the related color development unit.
Code: SC 373
Description: TD sensor [M] : Adjustment error During the developer initialization, the output value of the TD sensor is without the adjustment range (3.0 ± 0.1V).
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Remedy: 1. Turn the main switch off and on. 2. Reset the related color development unit. 3. Replace the related color development unit.
Code: SC 374
Description: Vt error [K] During the image development, Vt value is less than 0.5V.
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Remedy: 1. Turn the main switch off and on. 2. Reset the related color development unit. 3. Replace the related color development unit.
Code: SC 375
Description: Vt error [Y ]During the image development, Vt value is less than 0.5V.
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Remedy: 1. Turn the main switch off and on. 2. Reset the related color development unit. 3. Replace the related color development unit.
Code: SC 376
Description: Vt error [C] During the image development, Vt value is less than 0.5V.
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Remedy: 1. Turn the main switch off and on. 2. Reset the related color development unit. 3. Replace the related color development unit.
Code: SC 377
Description: Vt error [M] During the image development, Vt value is less than 0.5V.
Causes: • Poor connection (TD sensor outputs is less than 0.5V.) • Defective TD sensor
Remedy: 1. Turn the main switch off and on. 2. Reset the related color development unit. 3. Replace the related color development unit.