Description: Trailing edge laser detection error: [C] The laser synchronizing detection signal for LDB [C] of the trailing edge is not detected for one second after the LDB unit turned on when detecting the main scan magnification.
Causes: Disconnected cable from the laser synchronizing detection unit or defective connection. Defective laser synchronizing detector Defective LDB Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.
Code: 220
Description: Laser Synchronizing Detection Error: LDB of the leading edge [K] The laser synchronizing detection signal for LDB [K] of the leading edge is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally.tion.
Causes: Disconnected cable from the laser synchronizing detection unit or defective connection. Defective laser synchronizing detector. Defective LDB. Defective EGB.
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.
Code: 222
Description: Leading edge laser detection error: [Y] The laser synchronizing detection signal for LDB [Y] of the leading edge is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally.
Causes: Disconnected cable from the laser synchronizing detection unit or defective connection. Defective laser synchronizing detector. Defective LDB. Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.
Code: 224
Description: Leading edge laser detection error: [M] The laser synchronizing detection signal for LDB [M] of the leading edge is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally.
Causes: Disconnected cable from the laser synchronizing detection unit or defective connection. Defective laser synchronizing detector. Defective LDB. Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.
Code: 226
Description: Leading edge laser detection error: [C] The laser synchronizing detection signal for LDB [C] of the leading edge is not output for two seconds after LDB unit turns on while the polygon motor is rotating normally
Causes: Disconnected cable from the laser synchronizing detection unit or defective connection. Defective laser synchronizing detector. Defective LDB. Defective EGB
Remedy: 1. Check the connectors. 2. Replace the laser-synchronizing detector. 3. Replace the LDB. 4. Replace the EGB.
Code: 230
Description: FGATE: On error [K] The PFGATE ON signal does not assert within 5 seconds after processing the image in normal job or MUSIC for [K] starts.
Causes: Defective connection between the controller board and EGB. Defective cable between the EGB and LDB.
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.
Code: 231
Description: FGATE: Off error [K] The PFGATE ON signal still asserts within 5 seconds after processing the image in normal job or MUSIC for [K] ends. The PFGATE ON signal still asserts when the next job starts.
Causes: Defective connection between the controller board and EGB. Defective cable between the EGB and LDB.
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.
Code: 232
Description: FGATE: On error [Y] The PFGATE register of GAVD does not assert within 5 seconds after processing the image in normal job or MUSIC for [Y] started
Causes: Defective connection between the controller board and EGB. Defective cable between the EGB and LDB.
Remedy: 1. Check the connectors. 2. Replace the LDB. 3. Replace the EGB.