Các lỗi thường gặp

Code :
  • Code: 792-22
  • Description: Ring Binder (D392) Stack height error Stack height sensor remained ON while moving toward the top. -or- The sensor did not go ON within 6 sec. after the motor turned on.
  • Causes: • Stacker motor (M501) connector loose, broken, defective • Motor overload • Stack height sensor (S502) connector loose, broken, defective • Sensor defective
  • Remedy:
  • Code: 792-23
  • Description: Ring Binder (D392) Stacker error Although the stacker was full at the start and end of stacker operation with the stacker full (stacker sensors ON together), no documents were detected (also when documents were leaning) -or- Although the stacker was detected full with the stacker stopped, no documents were detected within 2 sec. (1st detection jam, 2nd detection SC error)
  • Causes: • Stacker HP sensor (S501) connector loose, broken, defective, or sensor defective • Stacker height HP sensor (S502) connector loose, broken, defective, or sensor defective • Stacker detect sensor (S504) loose, broken, defective, or sensor defective
  • Remedy:
  • Code: 792-3
  • Description: Ring Binder (D392) Pre-punch jogger roller HP error Detected at HP after the time prescribed to leave the HP had elapsed (more than 36 pulses) (1st detection, jam, 2nd detection, SC error) -or- Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 22 pulses) (1st detection, jam, 2nd detection, SC error)
  • Causes: • Jog roller lift motor (M305) connector loose, broken, defective • Motor overload • Motor defective • Jog roller lift HP sensor (S309) connector loose, broken, defective • Sensor defective
  • Remedy:
  • Code: 792-4
  • Description: Ring Binder (D392) Punch defective One or more of the following occurred: Punch unit not detected at initialization. No motor rotation detected at HP at 30 ms after the DC motor turned on No encoder pulse detected at HP at 5 ms after the DC motor turned on Not detected at HP at 400 ms after the DC motor turned on
  • Causes: • Punch motor (M304) connector loose, broken, defective • Motor overload • Motor defective • Punch HP sensor (S302) connector loose, broken, defective, or sensor defective • Punch encoder sensor (S303) connector loose, broken, defective, or sensor defective
  • Remedy:
  • Code: 792-5
  • Description: Ring Binder (D392) Paddle roller HP error Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)
  • Causes: • Paddle roller lift motor (M603) connector loose, broken, defective • Motor overload • Motor defective • Paddle roller HP sensor (S602) connector loose, broken, defective • Sensor defective
  • Remedy:
  • Code: 792-6
  • Description: Ring Binder (D392) Jogger fence 1 error Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)
  • Causes: • Jog fence 1 motor (M604) connector, loose, broken, defective • Motor defective • Motor overload • Side fence 1 HP sensor (S601) connector, loose, broken, defective • Sensor defective
  • Remedy:
  • Code: 792-7
  • Description: Ring Binder (D392) Jogger fence 2 error Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)
  • Causes: • Jog fence 2 motor (M606) connector, loose, broken, defective • Motor defective • Motor overload • Side fence HP sensor 1 (S611) connector loose, broken, defective • Sensor defective
  • Remedy:
  • Code: 792-8
  • Description: Ring Binder (D392) Stack tamper HP error Not detected at HP after the time prescribed to arrive at the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error) -or- Detected at HP after the time prescribed to leave the HP had elapsed (more than 400 ms) (1st detection, jam, 2nd detection, SC error)
  • Causes: • Stack tamper motor (M607) connector, loose, broken, defective • Motor defective • Motor overload • Stack tamper HP sensor (S612) connector loose, broken, defective • Sensor defective
  • Remedy:
‹ First  < 50 51 52 53 54 55 56 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục