Code :
- Code: 669
- Description: EEPROM Error
An unexpected value exists in the initialization flag of the EEPROM.
- Causes: EEPROM not initialized. Defective EEPROM.
- Remedy: 1. Initialize the EEPROM. 2. Replace the EEPROM. 3. Replace the EGB.
- Code: 690
- Description: GAVD Communication Error
The ID of the GAVD is not identified during initialization.
- Causes: Defective EGB
- Remedy: 1. Replace the EGB.
- Code: 819
- Description: Service Cycle Power
Incorrect combination of EGB and controller board. An unexpected error occurs in the EEPROM on the controller board
- Causes: Controller board defective
- Remedy: 1. Install the correct EGB and controller boards for this machine. 2. Replace the controller board
- Code: 823
- Description: USB/ Network Device Error
An interface error in the USB connection or NIB connection occurs.
- Causes: Controller board detective
- Remedy: 1. Replace the controller board.
- Code: 824
- Description: EEPROM Error
An EEPROM check error at power-on occurs.
- Causes: Controller board detective
- Remedy: 1. Replace the controller board.
- Code: 827
- Description: On-Board Memory Check Error
An on-board memory check error at power-on occurs.
- Causes: Controller board detective
- Remedy: 1. Replace the controller board.
- Code: 828
- Description: ROM Checksum Error
- Causes: A ROM checksum error at power-on occurs.
- Remedy: 1. Replace the controller board.