Description: Consecutive fusing jam The paper jam counter for the fusing unit reaches 3 times. The paper jam counter is cleared if the paper is fed correctly. This SC is activated only when SP1159-001 is set to "1" (default "0").
Causes: • Paper jam in the fusing unit
Remedy: Remove the paper that is jammed in the fusing unit. Then make sure that the fusing unit is clean and has no obstacles in the paper feed path.
Code: 561
Description: Pressure roller thermistor error The temperature detected by the pressure roller thermistor does not reach 0 °C for 20 seconds.
Causes: • Loose connection of the pressure roller thermistor • Defective thermopile • Defective pressure roller thermistor
Remedy: 1. Check if the pressure roller thermistor is firmly connected. 2. Replace the thermopile. 3. Replace the pressure roller thermistor. No.
Code: 563
Description: Pressure roller overheat (software error) The temperature detected by the pressure roller thermistor stays at 230°C or more for 1 second.
Remedy: 1. Replace the PSU. 2. Replace the IPU. 3. Replace the BCU.
Code: 564
Description: Pressure roller overheat (hardware error) The temperature detected by the pressure roller thermistor detects 250°C or more.
Causes: • Defective PSU • Defective IPU • Defective BCU • Defective fusing control system
Remedy: 1. Replace the thermistor. 2. Replace the PSU. 3. Replace the IPU. 4. Replace the BCU.
Code: 565
Description: Pressure roller fusing lamp consecutive full power When the fusing unit is not running in the ready condition, the pressure roller fusing lamp keeps ON full power for 300 seconds or more.
Remedy: 1. Check the cable connection of the ARDF. 2. Shut out the external noise. 3. Replace the ARDF. 4. Replace the BCU board.
Code: 621
Description: Finisher communication error While the BCU communicates with an optional unit, an SC code is displayed if one of following conditions occurs. • The IPU receives the break signal which is generated by the peripherals only just after the main switch is turned on. • When the BCU does not receive an OK signal from a peripheral 100ms after sending a command to it. The IPU resends the command. The IPU does not receive an OK signal after sending the command 3 times.
Causes: • Cable problems • IPU problems • BCU problems • PSU problems in the machine • Main board problems in the peripherals
Remedy: 1. Check if the cables of peripherals are correctly connected. 2. Replace the PSU if no power is supplied to peripherals. 3. Replace the IPU or main board of peripherals. 4. Replace the BCU.