Description: Heating roller fusing lamp consecutive full power 1 When the fusing unit is not running in the ready condition, the heating roller fusing lamp keeps on full power for 30 seconds.
Remedy: 1. Replace the heating roller thermostat. 2. Replace the heating roller fusing lamp.
Code: 547
Description: Zero cross error • The zero cross signal is detected for 0.05 seconds three times even though the heater relay is off when turning on the main power. • The zero cross signal is not detected for 3 seconds even though the heater relay is on after turning on the main power or closing the front door. • The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45.
Remedy: 1. Check the power supply source. 2. Replace the shorted 24V fuse on the PSU. 3. Replace the PSU
Code: 551
Description: Heating roller thermistor (end) error 2 The temperature measured by the heating roller thermistor (end) does not reach 0° C for 6 seconds.
Remedy: 1. Check that the heating roller thermistor (end) is firmly connected. 2. Replace the heating roller thermistor (end).
Code: 552
Description: Heating roller warm-up error 2 The heating roller temperature does not reach the ready temperature while 70 seconds after the heating lamp on.
Remedy: 1. Check if the heating roller thermistor (end) is firmly connected. 2. Replace the heating roller thermistor (end). 3. Replace the heating roller fusing lamp.
Code: 553
Description: Heating roller fusing lamp overheat 2 (software error) The detected pressure roller temperature stays at 230°C or more for 1 second.
Causes: • Defective PSU • Defective BCU
Remedy: 1. Replace the heating roller thermistor (end). 2. Replace the PSU. 3. Replace the BCU.
Code: 554
Description: Heating roller fusing lamp overheat 2 (hardware error) The heating roller thermistor (end) detects 250°C or more.
Causes: • Defective heating roller thermistor (end) • Defective PSU • Defective BCU • Defective fusing control system
Remedy: 1. Replace the heating roller thermistor (end). 2. Replace the PSU. 3. Replace the BCU.
Code: 555
Description: Heating roller lamp consecutive full power 2 When the fusing unit is not running in the ready condition, the pressure roller-fusing lamp keeps ON full power for 8 seconds or more.
Remedy: 1. Replace the heating roller thermostat. 2. Replace the heating roller fusing lamp.
Code: 557
Description: Zero cross frequency error When the zero cross signal is 66 or more and it is detected 10 times or more in 11 detections, the machine determines that input 60 Hz and SC557 occurs.