Các lỗi thường gặp

Code :
  • Code: A2
  • Description: The document is too long. (During scanning, 90 cm or longer of a document is detected.)
  • Causes: Document rear actuator not operating smoothly or catching in some position.
  • Remedy: 1 Document rear actuator not operating smoothly or catching in some position. Ensure smooth operation and that there is no catching of document rear actuator.
  • Code: A3
  • Description: Document rear sensor is not turned on when feeding the document.
  • Causes: Document rear actuator not operating smoothly or catching in some position. Document rear sensor failure. ADF motor failure
  • Remedy: 1 Document rear actuator not operating smoothly or catching in some position. Ensure smooth operation and that there is no catching of document rear actuator. 2 Document rear sensor failure. Replace the document rear sensor. 3 ADF motor failure Replace the ADF motor.
  • Code: A5
  • Description: Fax scanning error (First warning only)
  • Causes: Scanning failure.
  • Remedy: 1 Scanning failure Turn the power switch off and on. Then, try scanning again.
  • Code: A6
  • Description: Fax scanning error (After the A5 error occurs, the same problem occurs again even after turning the power off and on.)
  • Causes: FB unit failure. Main PCB failure.
  • Remedy: 1 FB unit failure Replace the FB unit. 2 Main PCB failure Replace the main PCB ASSY.
  • Code: AD
  • Description: DMA transfer error
  • Causes: FB unit failure. Main PCB failure.
  • Remedy: 1 FB unit failure Replace the FB unit. 2 Main PCB failure Replace the main PCB ASSY
  • Code: AF
  • Description: FB unit home position failure
  • Causes: FB unit failure. Main PCB failure.
  • Remedy: 1 FB unit failure Replace the FB unit. 2 Main PCB failure Replace the main PCB ASSY.
  • Code: B0
  • Description: Harness for scanning is not connected correctly.
  • Causes: Scanner harness not connected correctly. Scanner harness broken. Main PCB failure
  • Remedy: 1 Scanner harness not connected correctly. Reconnect the scanner harness correctly. 2 Scanner harness broken Replace the FB unit. 3 Main PCB failure Replace the main PCB ASSY.
  • Code: B7
  • Description: Detection error of scanner (Scanning reference voltage adjustment malfunction.)
  • Causes: FB unit failure. Main PCB failure.
  • Remedy: 1 FB unit failure Replace the FB unit. 2 Main PCB failure Replace the main PCB ASSY.